Setpoint function
0-4
0
0=not used
1=overload gross (only 1 setpoint used)
2=overload gross (only 1 setpoint used)
3=Printer (without date/time/switched supply)
4=not used
17
Application
Basic (standard) or Peakhold (Phold)
BASIC
18
Gravity value working area
9.750-9.850
9.797
19
Key function
Remote - Local - Both
Local
20
Baudrate comport 1
600-1200-2400-4800-9600-19200
9600
21
Databits comport 1
7-8
8
22
Parity comport 1
none/odd/even
none
23
Stopbits comport 1
1-2
1
24
Not used
25
Dataprotocol comport 1
0-4
0
0=PC bi-directional command structure
1=not used
2=Remote display continuously
3=Printer (without date/time/switched supply)
4=not used
26
Number of linefeeds comport 1
0-9
0
27-29
Not used
30
Baudrate comport 2
600-1200-2400-4800-9600-19200
9600
31
Databits comport 2
7-8
8
32
Parity comport 2
none/odd/even
none
33
Stopbits comport 2
1-2
1
34
Not used
35
Dataprotocol comport 2
0-4
3
0=PC bi-directional command structure
1=not used
2=Remote display continuously
3=Printer (without date/time/switched supply)
4=not used
Parameter
Function
Settings
Default
US