8
Fast temperature changes should be avoided because condensation may form in the electronics.
During acclimatization the indicator must be turned off.
Taking the System into Operation
To activate the scale, turn it on using the on/off (
) button on the terminal.
After 3 to 5 minutes the electronics and load cells have reached the operational temperature. Before
this, inaccuracies of up to 0.3% may occur.
It is recommended not to lift loads before the zero-point correction is executed. (See
“TROUBLESHOOTING” on page 20).
Maintenance
The maintenance guidelines for normal pallet trucks apply to the chassis of the mobile scale. The
integrated scale functions even though the chassis is damaged by overloading.
Main guidelines:
•
Because the steering wheels are mounted in the front, pulling of the pallet truck is preferred
above pushing it.
•
When the lifting mechanism is not used, the handle should be kept in the neutral (middle)
position. This prolongs the life-span of the seals.
•
The scale meets up to the protection class NEMA 4/IP65. This means that dust or moisture (rain
or water beam from all sides) does not influence the operation of the electronics. However,
high-pressure cleansing in combination with warm water or chemical cleansers
leads to the
entry of moisture and has a negative influence on the operation of the system.
•
To avoid damage to load cells and electronics, only the Authorized Service Center may
undertake any welding.
•
The bearings of the wheels (non-polyurethane) and the pivoting points of the leveling bar of the
loading wheels must be cleansed and greased regularly.