Lift-Rite,
Tel:
Toll Free from USA: 1-800-558-6012, Greene, NY 13778, Publication Number 1234959D ©2022 Dated 14 Sep 2022
20
TROUBLESHOOTING
Use the troubleshooting procedures shown in the following table as a guide only.
CONDITION
SUB-
CONDITION
POSSIBLE
CAUSE
ACTION
No lifting
Pump does not
lift the load.
An air lock in the
hydraulic
system.
Pull up on the fingertip control and hold while
pumping the handle 8 to 10 times to bleed air from
the system.
Lifting, neutral,
and lowering
do not function
properly.
Chain anchor is
out of
adjustment.
Turn the nut on the chain anchor clockwise until the
pumping action, while in neutral, does not raise the
forks.
Forks raise and
sink with pump
action.
Dirt or foreign
particle is caught
in the cone valve
seat.
Pull up on the fingertip control and hold while
pumping the handle 8 to 10 times to purge the
valve system.
Indicator is
not
responsive
Blank screen.
Empty or
defective battery
Use a fully charged battery pack. (See “The Battery”
on page 6.)
Component
damage.
Short or
humidity.
Measure 12VDC across the battery terminals. If the
multimeter reads 12VDC, replace the board.