12
EL0030
EL0030
1
2
3
4
5
6
7
8
9
10
F1
F2
UOMOPRESENTE
SEMIAUTOMA
TICO
AUTOMA
TICO 2 P
ASSI
BLACH-OUT
AUTOMA
TICO 4 P
ASSI
CONDOMINIALE
PRELAMPEGGIO
LAMPEGGIO IN P
AUSA
FOTO
1
CHIUDE P
ASSANDO
FOTO TEST
COLPO D`ARIETE
LUCE DI COR
TESIA
RALL APER
TURA
APER
T. PEDONALE
FORZA
TEMPO P
AUSA
RALLENT
AMENTO IN CHIUSURA
SENSIBILIT
A` MOTO
EL0023c
EL0023c
1
2
3
4
5
6
7
8
9
10
F1
F2
UOMOPRESENTE
SEMIAUTOMA
TICO
AUTOMA
TICO 2 P
ASSI
BLACH-OUT
AUTOMA
TICO 4 P
ASSI
CONDOMINIALE
PRELAMPEGGIO
LAMPEGGIO IN P
AUSA
FOTO
1
CHIUDE P
ASSANDO
FOTO TEST
COLPO D`ARIETE
LUCE DI COR
TESIA
RALL APER
TURA
APER
T. PEDONALE
FORZA
TEMPO P
AUSA
RALLENT
AMENTO IN CHIUSURA
SENSIBILIT
A` MOTO
EL0023b
EL0023b
1
2
3
4
5
6
7
8
9
10
F1
F2
UOMOPRESENTE
SEMIAUTOMA
TICO
AUTOMA
TICO 2 P
ASSI
BLACH-OUT
AUTOMA
TICO 4 P
ASSI
CONDOMINIALE
PRELAMPEGGIO
LAMPEGGIO IN P
AUSA
FOTO
1
CHIUDE P
ASSANDO
FOTO TEST
COLPO D`ARIETE
LUCE DI COR
TESIA
RALL APER
TURA
APER
T. PEDONALE
FORZA
TEMPO P
AUSA
RALLENT
AMENTO IN CHIUSURA
SENSIBILIT
A` MOTO
EL0031
EL0031
1
2
3
4
5
6
7
8
9
10
F1
F2
UOMOPRESENTE
SEMIAUTOMA
TICO
AUTOMA
TICO 2 P
ASSI
BLACH-OUT
AUTOMA
TICO 4 P
ASSI
CONDOMINIALE
PRELAMPEGGIO
LAMPEGGIO IN P
AUSA
FOTO
1
CHIUDE P
ASSANDO
FOTO TEST
COLPO D`ARIETE
LUCE DI COR
TESIA
RALL APER
TURA
APER
T. PEDONALE
FORZA
TEMPO P
AUSA
RALLENT
AMENTO IN CHIUSURA
SENSIBILIT
A` MOTO
EL0016
EL0016
A
EL0036a
EL0036a
1
2
3
4
5
6
7
8
9
10
F1
F2
UOMOPRESENTE
SEMIAUTOMA
TICO
AUTOMA
TICO 2 P
ASSI
BLACH-OUT
AUTOMA
TICO 4 P
ASSI
CONDOMINIALE
PRELAMPEGGIO
LAMPEGGIO IN P
AUSA
FOTO
1
CHIUDE P
ASSANDO
FOTO TEST
COLPO D`ARIETE
LUCE DI COR
TESIA
RALL APER
TURA
APER
T. PEDONALE
FORZA
TEMPO P
AUSA
RALLENT
AMENTO IN CHIUSURA
SENSIBILIT
A` MOTO
EL0016
EL0016
A
2)
Pedestrian command identification the red LED
(DX)
will flash slowly and the flashing light will emit
double flashes.
Press the key
(A)
on the radio control(s) (not ma
-
ster) that one wants to identify and hold down until
the green LED
(DX)
and the
SPLENDOR
flashing
light light briefly.
3)
Radio control resetting: the red and green LEDs
(DX)
and
(SX)
will flash alternately and the flashing
light will emit a triple flash.
Press the key
(A)
on the radio control(s) (not ma
-
ster) that one wants to reset and hold down until the
green LED and the
SPLENDOR
flashing light light
briefly.
4)
Exit programming
.
a)
That the 2 red LEDs flash.
b)
Check that the lateral LEDs
L7
and
L11
are
switched on.
c)
Check that the lateral LEDs
L8
,
L9
and
L10
are
switched off.
If this does not occur, check the connections and
effectiveness of the various devices, assure that the
NC inputs for which no device is connected are
jumpered.
2.3.1 Travel and staggering identification
2.3.1.1 2-leaf gate
There are two initial programming modes available:
a)
ONE TOUCH’
: automatic programming in which the various operations are performed automatically with default settings established by
LIFE. This mode is recommended for lightweight leafs and openings of up to 90°.
b) STANDARD:
the initial manoeuvres are controlled by the fitter.
A) ‘ONE TOUCH’ PROGRAMMING
a)
Press .
b)
Press the step command key
(A)
on the radio control: the automation will perform, in sequence, a closure, an opening, a closure.
c)
Having completed the gate(s) close self-programming, the two green LEDs flash and the red one remains lit.
The automation is now in
semi-automatic
mode by default.
Perform standard installation if you are dissatisfied with the result obtained.
2.3 INITIALISATION
ATTENTION: LIFE cards are multipurpose and may be used for several applications; therefore, on activation they require the identi
-
fication of the type of automation that they will serve.
EL0043
EL0043
EL0043A
EL0043A
X2
EL0043
EL0043
EL0043A
EL0043A
X3
2)
3)
a) The control unit must NOT be powered electrically.
b) Release the actuator, position the leafs at approximately 50 cm from the closure position and re-lock them. ( OPERATOR RELEASE Chap.)
c) Press and together, holding them down, and switch on the power supply to the control unit.
d) Release the keys when the red LED lights
N.B.
The operations described in point c) and d) allow operator identification and have already been performed by the Manufacturer, it is therefore
sufficient to switch on the power supply and check: .
ATTENTION: Each phase has a timed exit (after approx.15 secs.) from receiver programming feature.
L7
L8
L9
L10
L11
2 MAN.ISTRUZ.GE UNI24R (GB).indd 12
30-10-2008 16:41:17