• It is constituted by a membrane keyboard divided by a central column
of keys, (from to ) into two vertical areas: the right-hand keyboard
(black/blue) and the left-hand keyboard ( grey/yellow). Each vertical key
-
board manages and memorises certain operation parameters.
• The selection of the right or left keyboard takes place by pressing one
of the two buttons with the symbol
(A)
or
(B)
: the button activates the
TERMINAL STRIP
(SX)
, and button selects the TERMINAL STRIP
(DX)
.
• Keyboard de-selection takes place automatically after a certain interval
of time from the last key pressed with the exception of the
FORCE
function, which remains active until another function is selected.
9
1
2
A
B
3
4
5
6
10
7
8
9
F1
F2
T0004
SX
DX
• When the LEDs (DX) and (SX) flash alternately, it is possible to set parameters to .
EL0028
EL0028
1
2
3
4
5
6
7
8
9
10
F1
F2
UOMOPRESENTE
SEMIAUTOMA
TICO
AUTOMA
TICO 2 P
ASSI
BLACH-OUT
AUTOMA
TICO 4 P
ASSI
CONDOMINIALE
PRELAMPEGGIO
LAMPEGGIO IN P
AUSA
FOTO
1
CHIUDE P
ASSANDO
FOTO TEST
COLPO D`ARIETE
LUCE DI COR
TESIA
RALL APER
TURA
APER
T. PEDONALE
FORZA
TEMPO P
AUSA
RALLENT
AMENTO IN CHIUSURA
SENSIBILIT
A` MOTO
EL0029
EL0029
1
2
3
4
5
6
7
8
9
10
F1
F2
UOMOPRESENTE
SEMIAUTOMA
TICO
AUTOMA
TICO 2 P
ASSI
BLACH-OUT
AUTOMA
TICO 4 P
ASSI
CONDOMINIALE
PRELAMPEGGIO
LAMPEGGIO IN P
AUSA
FOTO
1
CHIUDE P
ASSANDO
FOTO TEST
COLPO D`ARIETE
LUCE DI COR
TESIA
RALL APER
TURA
APER
T. PEDONALE
FORZA
TEMPO P
AUSA
RALLENT
AMENTO IN CHIUSURA
SENSIBILIT
A` MOTO
2 STARTING UP
2.1 Description of the keyboard
The keyboard on the control unit makes it possible to set all the functions necessary for a safe and controlled functioning of the automation.
• The buttons and are used to vary the values or parameters.
• The horizontal row of red LEDs from 1 to 5 indicates the value set for a given parameter: the more LEDs lit, the higher the
parameter value.They are also used as a status indicator for certain parameters.
• The lateral red LEDs indicate a non-set parameter status if they flash: , and they indicate the detection of the stop plate signal (right or left)
when they are lit: .
• the lateral green LEDs indicate a parameters set or correct function status according to the keyboard selected.
1.7.3 Indicator LEDs
There is a row of 5 LEDs on the right hand side of the board, under the terminals. These LEDs are lit when the corresponding signal is present. For
the NC inputs, stop and photo, the corresponding LEDs L7 and L11 are normally lit; for the NO inputs open, close and step, the corresponding LEDS
L8, L9 and L10 are normally off. These LEDs therefore indicate any malfunction of the connected devices.