8
5 s
10 s
30 s
60 s
120 s
1
2
1
2
+
+
+
+
+
+
5”
+
+
+
+
+
+
4 REGOLATIONS AND OPTIONS
4.1 AUTOMATIC CLOSURE
An automatic closure is activated after a set PAUSE TIME.
4.2 AUTOMATIC CLOSURE
a) Press the button the green right Led turns on
- If none of the leds is turned on the
Wait 20” or press the button again
in order to anticipate the exit from programming mode.
automatic closure is not active , press the
button to activate it .
- If at least one of the leds is on
the automatic closure is activated, in order to
deactivate it press the button untill all of the
Leds are off.
By pressing and you can set the various
values for the PAUSE TIME
Work cycle:
OPEN - PAUSE - CLOSE - PAUSE
MINIMUM
4.3 ADJUSTMENT TIME OF DECELERATION
a) Press the for 5” the Led green and red on the
right will turn on:
ATTENTION
:
The deceleration CAN’T be completely eliminated , in this phase the limit switch’s push force will determine
the Stop in the motor’s run.
By pressing and you can adjust the value
of he DECELERATION TIME
MAXIMUM
DEFAULT
LEDS ON
LEDS ON
PAUSE TIME
DECELERATION TIME
CHIUSURA NON ATTIVA
+
+
+
+
+
Wait 20” or press the button again
in order to anticipate the exit from programming mode.
OPTIONS SETTING
Automatic reclosure is activated after a preset PAUSE TIME.
AUTOMATIC RE-CLOSURE IS NOT
ENABLED
SLOWDOWN TIME ADJUSTMENT
the green and red LEDs on the right
light up:
the SLOWDOWN TIME
The slowdown can NOT be completely eliminated, in this phase the thrust in the limit switch determines the stop of
the motor stroke.