11
1
2
2
1
1
2
1
2
1
2
1
2
1
2
2
1
7 MANUAL PROGRAMMING
Press for 5 seconds , the 5 leds will light up and then
start blinking.
Manual programming can be done with a button
connected to terminals 6 - 10 (Step-by-Step) or with
radio control previously memorized, page 7 cap.3.1.
Position the motors at 45 °.
7.1 CLOSING FINISHES LEARNING
During the flashing of the 5 LEDs give a command of
Step by step the leaf [2] must move first in closing,
when he arrives at the stop he has to stop and the Led of the
Right goes on with fixed red light.
Give a second Step-by-Step command the leaf [1] must
move in closing, when it comes in batting it must stop and
the Left LED lights up with a fixed red light.
Give a Step-by-Step command the leaf [1] opens, al
reaching the point where you want to open also
the leaf [2] give a further step-by-step command.
The two wings now proceed in opening until they reach the
respective mechanical stops, the two red LEDs of left and
right they remain in red light.
Give a Step-by-Step command the leaf [2] closes, al
reaching the point where you want to close also
the leaf [1] give a further step-by-step command.
The two doors proceed now in closing until they reach the
respective mechanical stops, the two red LEDs of left and
right they remain in red light.
7.3 LEARNING CLOSING OFFSET
7.2 LEARNING OFFSET AND FINISHES
The automation is now programmed in semi-automatic mode.
If the result obtained is not satisfactory, perform the
reset the control panel and restart from point 7.
START
Manual programming can be done with a button connected
to terminals 6 - 10 (Step-by-Step) or with the previously
memorized radio control, page 7 chap. 3.1.
Place the motors (leaves) at 45 °.
Hold the START button for 5 seconds, the 5 LEDs first light
up and then flash.
CLOSING LIMIT SWITCH LEARNING
While the 5 LEDs are flashing, give a Step-by-Step
command; the leaf [2] must move first performing a closure;
when it reaches the mechanical stop it must stop and the
Right LED lights up with a red steady light.
Give a second step-by-step command; the leaf [1] must
perform a closure, when it reaches the mechanical stop it
must stop and the Left LED lights up with a red steady light.
OPENING AND CLOSING PHASE SHIFT LEARNING
Give a Step-by-Step command; the leaf [1] starts opening; as
soon as it reaches the point where you want to start opening
leaf [2] give a further Step-by-Step command.
The two leaves now proceed to open until they reach their
respective mechanical stops, the two red LEDs on the left
and on the right remain with a steady red light.
OPENING PHASE SHIFT AND LIMIT SWITCHES LEARNING
CLOSING PHASE SHIFT LEARNING
Give a Step-by-Step command; the leaf [2] starts closing; as soon as
it reaches the point where you want to start closing leaf [1] give a
further Step-by-Step command.
The two leaves now proceed to close until they reach their
respective mechanical stops, the two red LEDs on the left and on
the right remain with a steady red light.
Automation is now programmed in semi-automatic mode.
If the result obtained is not satisfactory, carry out the
reset the control unit and start again from point 7.
LEARNING OF THE CLOSURE LIMIT SWITCH
LEARNING OF OPENING PHASE LAG AND LIMIT SWITCH
LEARNING OF CLOSING PHASE LAG