background image

6

OFF

230V

OFF

1

3

ON

ON

230V

2

OF

F

230V

OFF

230V

OFF

1

2

ON

ON

230V

Energy Saving

1

2

1

2

In order to optimize electrical consumption 
we introduced the ES function.
After 10’ from the central 
programmation the Leds of the front 
panel will turn off and the keyboardwill 
be deactivated.
To re-activate the keyboard turn the 
central unit off and on again  

 2.2  RUN PROGRAMMATION AND SHUTTERS OFFSET

will first turn on and then they will blink.

As soon as this process is done the two green Leds will start blinking  , while the two red Leds will stay  on   

If the result is not satisfying it is possible to execute a manual programmation to define different 
offsets.Refer to chapter n°7.

a)   Position the shutters at a 45° angle. 

b)  Press the           button for 5” , the 5 Leds   

c)  Press         the gate will execute this sequence : 

 
-  Closing Shutter 2, 
-  Closing Shutte 1,
-  Opening Shutter 1, with offset 
-  Opening  Shutter 2, 
-  Closing Shutter 2, with offset 
-  Closing Shutter 1.

N.B. In case only one motor is being used connect it with the n°35 and n°36 clamps.
Make sure to fix the mechanical limit switches of opening and closing of the automation

When the programmation is done for 10 minutes the         button can be used as a STEP command 

N.B. 
In order to totally reset the unit , before giving power, press and keep pushed the          button, release 
after the central unit.  

2   CENTRAL UNIT PROGRAMMATION

 2.1  TOTAL RESET

ATTENTION 

START

START

START

START

To optimize energy consumption, 
we have introduced the Energy
Saving function. After 10 minutes 
from the control unit setup, the front
panel LEDs turn off and the use of 
the keyboard is inhibited. To
reactivate it, it is necessary to switch 
the control unit off and on again.

CONTROL UNIT SETUP

Power off the system, hold the start button, power on again and release the start button once the 
red leds come on.

PROGRAMMING THE TRAVEL AND THE LEAVES’ SHIFT

N.B. If only one motor is used, connect it to terminals 35 - 36.
Make sure you have fixed the mechanical opening and closing limit switches of the automation.

Place the leaves at 45°

Press and hold down the START button for 

5 seconds until all 5 red LED’S blink.

Press START, the automation performs in sequence:
- closure leaf 2;
- closure leaf 1;
- opening leaf 1, with phase shift;
- opening leaf 2;
- closure leaf 2, with phase shift;
- closure leaf 1.

Once programming is complete, the two green LEDs will flash, while the two red LEDs will turn on with 
a steady light.

The START key at the end of programming, for 10 minutes can be used as a STEP command

If the result is not satisfactory, it is possible to carry out a manual programming to define the different 
phase shifts. See chapter No. 7.

LAG

lag;

lag;

PHASE LAG

PROGRAMMING THE TRAVEL AND PHASE LAG

lags

Summary of Contents for CT2 24 UNI DL

Page 1: ...Rev 01 26 2018 LG CT2 24 UNI DL 24V F CONTROL UNIT FOR TWO LEAF GATES INSTRUCTIONS AND WARNINGS FOR INSTALLATION USE AND MAINTENANCE GB ...

Page 2: ... manufacturer its maintenance Important safety instructions For personal safety it is important to follow these instructions Keep these instructions The device must be disconnected from the power supply during cleaning and maintenance operations and the replacement of components Do not allow children to play with the gate control devices Keep remote controls away from children Monitor the moving g...

Page 3: ...3 mm 250 mm 184 min cm 40 5 3 4 1 2 GEBOX ASSEMBLY INSTRUCTIONS ...

Page 4: ...ESCRIPTIONS AND WARNINGS FOR SECURITY and PRESCRIPTIONS AND WARNINGS FOR THE INSTALLATION All of the linking and connecting operations must be performed with the power source disconnected if the device is not visible a sign must be applied WARNING UNDER MAINTENANCE Stocking antenna input use RG58 50 Ohm cable ANTENNA For the imputs STOP OPEN CLOSE STEP BY STEP PHOTO BLINKER PEDESTRIAN Connections ...

Page 5: ...der the terminal block show the entry state L7 and L11 are imputs N C and must be turned on they turn off when the corresponding imput is activated L8 L9 L10 are imputs N O must be turned off and they will automatically turn on when the corresponding imput is activated COMMON COMMANDS Relay PEDESTRIAN SIGNALING LED The LEDs under the terminal block indicate the state of the entrance L7 and L11 are...

Page 6: ...press and keep pushed the button release after the central unit 2 CENTRAL UNIT PROGRAMMATION 2 1 TOTAL RESET ATTENTION START START START START To optimize energy consumption we have introduced the Energy Saving function After 10 minutes from the control unit setup the front panel LEDs turn off and the use of the keyboard is inhibited To reactivate it it is necessary to switch the control unit off ...

Page 7: ...e control unit is fitted with a built in radio receiver with a 750 code memory and 2 channels with a 433 92 MHz frequency with LIFE Rolling Code and Auto code encoding Press the key fob selection button top left the left green LED under symbol and the first red dot A beside symbol will light up Hold down the P1 button on the transmitter that you want to pair to perform a total opening until all fi...

Page 8: ...E CLOSE PAUSE MINIMUM 4 3 ADJUSTMENT TIME OF DECELERATION a Press the for 5 the Led green and red on the right will turn on ATTENTION The deceleration CAN T be completely eliminated in this phase the limit switch s push force will determine the Stop in the motor s run By pressing and you can adjust the value of he DECELERATION TIME MAXIMUM DEFAULT LEDS ON LEDS ON PAUSE TIME DECELERATION TIME CHIUS...

Page 9: ...IMIUM DEFAULT LED ON SPEED MINIMUM 75 a Press the button and left red led will turn on By pressing or the speed can be adjusted MAXIMUM 100 DEFAULT 90 LED ON ATTENTION Based on the gate s structure and on its usage parameters such as sensitivity and speed mus be setted accordingly to the laws of the country By pressing or the sensitivity can be adjusted Wait 20 or press the button again to anticip...

Page 10: ...interventions during movement Funcioning with PRESENT MAN Wait for 20 or press the again to exit programming mode No active function Wait for 20 or press the again to exit programming mode button to enter the OPTION MENU 1 then press it again in sequence to scroll through the available options The flashing LEDS indicate the position and the corresponding option By pressing button the function is a...

Page 11: ...rogramming can be done with a button connected to terminals 6 10 Step by Step or with the previously memorized radio control page 7 chap 3 1 Place the motors leaves at 45 Hold the START button for 5 seconds the 5 LEDs first light up and then flash CLOSING LIMIT SWITCH LEARNING While the 5 LEDs are flashing give a Step by Step command the leaf 2 must move first performing a closure when it reaches ...

Page 12: ...Address Via Sandro Pertini 3 5 31014 COLLE UMBERTO TV Italia Telephone 39 0438 388592 Telefax 39 0438 388593 http www homelife it e mail info homelife it ...

Reviews: