background image

 10 

5”

+

+

+

+

+

+

+

+

+

+

+

+

.............................................................................      

6    OPTIONS MENU 

6.1  OPTIONS 1

LED ON

OPTIONS  1

Press the             button in order to enter insde the OPTIONS MENU 1  , press in sequence the        

buttonto advance in the selection , the blinking led will indicate the poeistion , with the      button it will be 

activated Red fixed Led , with the        button it is deactivated.    

No active function.     

Condominium: Command Step Open only.     

Mode: OPEN-STOP-CLOSE-STOP.     

Electric lock activation.      

The imput CLOSE becomes PHOTO1.      

The activation of PHOTO anticipates the closure.      

6.2  OPTIONS 2  

LED ON

OPTIONS 2

Press the             button for 5” in order to enter the OPTION MENU 2 , press in sequence the             button 

to advance in the selection the led blinking shows the position and with the      button it is activated , fixed 

red Led, with the         button it deactivates .    

Faster slowing-down speed.     

The exit Relè 12-13 becomes a COURTESY LIGHT     

Delay of safety interventions during movement.    

Funcioning with PRESENT MAN.      

.............................................................................      

Wait for 20” or press the           again to exit programming mode. 

+

No active function.     

Wait for 20” or press the           again to exit programming mode. 

+

button to enter the OPTION MENU 1. then press it again in sequence to scroll through the available

options. The flashing LEDS indicate the position and the corresponding option. By pressing the function is activated 

(red led on), by pressing button – the function is deactivated

s

Condo options: step command only opening

Change operating mode: OPEN-STOPCLOSE-STOP

The CLOSE input becomes PHOTO1.

Activating PHOTO anticipates closure.

then press it again in sequence to scroll

through the available options. The flashing LEDS indicate the position and the corresponding option. By pressing 

the function is activated (red led on), by pressing button – the function is deactivated

s

Increase the speed during slowdown

The output Relay 12 - 13 becomes COURTESY LIGHT.

Safety intervention delay during movement.

Operation in MAN'S SWITCH

OPEN-STOP-CLOSE-STOP

Summary of Contents for CT2 24 UNI DL

Page 1: ...Rev 01 26 2018 LG CT2 24 UNI DL 24V F CONTROL UNIT FOR TWO LEAF GATES INSTRUCTIONS AND WARNINGS FOR INSTALLATION USE AND MAINTENANCE GB ...

Page 2: ... manufacturer its maintenance Important safety instructions For personal safety it is important to follow these instructions Keep these instructions The device must be disconnected from the power supply during cleaning and maintenance operations and the replacement of components Do not allow children to play with the gate control devices Keep remote controls away from children Monitor the moving g...

Page 3: ...3 mm 250 mm 184 min cm 40 5 3 4 1 2 GEBOX ASSEMBLY INSTRUCTIONS ...

Page 4: ...ESCRIPTIONS AND WARNINGS FOR SECURITY and PRESCRIPTIONS AND WARNINGS FOR THE INSTALLATION All of the linking and connecting operations must be performed with the power source disconnected if the device is not visible a sign must be applied WARNING UNDER MAINTENANCE Stocking antenna input use RG58 50 Ohm cable ANTENNA For the imputs STOP OPEN CLOSE STEP BY STEP PHOTO BLINKER PEDESTRIAN Connections ...

Page 5: ...der the terminal block show the entry state L7 and L11 are imputs N C and must be turned on they turn off when the corresponding imput is activated L8 L9 L10 are imputs N O must be turned off and they will automatically turn on when the corresponding imput is activated COMMON COMMANDS Relay PEDESTRIAN SIGNALING LED The LEDs under the terminal block indicate the state of the entrance L7 and L11 are...

Page 6: ...press and keep pushed the button release after the central unit 2 CENTRAL UNIT PROGRAMMATION 2 1 TOTAL RESET ATTENTION START START START START To optimize energy consumption we have introduced the Energy Saving function After 10 minutes from the control unit setup the front panel LEDs turn off and the use of the keyboard is inhibited To reactivate it it is necessary to switch the control unit off ...

Page 7: ...e control unit is fitted with a built in radio receiver with a 750 code memory and 2 channels with a 433 92 MHz frequency with LIFE Rolling Code and Auto code encoding Press the key fob selection button top left the left green LED under symbol and the first red dot A beside symbol will light up Hold down the P1 button on the transmitter that you want to pair to perform a total opening until all fi...

Page 8: ...E CLOSE PAUSE MINIMUM 4 3 ADJUSTMENT TIME OF DECELERATION a Press the for 5 the Led green and red on the right will turn on ATTENTION The deceleration CAN T be completely eliminated in this phase the limit switch s push force will determine the Stop in the motor s run By pressing and you can adjust the value of he DECELERATION TIME MAXIMUM DEFAULT LEDS ON LEDS ON PAUSE TIME DECELERATION TIME CHIUS...

Page 9: ...IMIUM DEFAULT LED ON SPEED MINIMUM 75 a Press the button and left red led will turn on By pressing or the speed can be adjusted MAXIMUM 100 DEFAULT 90 LED ON ATTENTION Based on the gate s structure and on its usage parameters such as sensitivity and speed mus be setted accordingly to the laws of the country By pressing or the sensitivity can be adjusted Wait 20 or press the button again to anticip...

Page 10: ...interventions during movement Funcioning with PRESENT MAN Wait for 20 or press the again to exit programming mode No active function Wait for 20 or press the again to exit programming mode button to enter the OPTION MENU 1 then press it again in sequence to scroll through the available options The flashing LEDS indicate the position and the corresponding option By pressing button the function is a...

Page 11: ...rogramming can be done with a button connected to terminals 6 10 Step by Step or with the previously memorized radio control page 7 chap 3 1 Place the motors leaves at 45 Hold the START button for 5 seconds the 5 LEDs first light up and then flash CLOSING LIMIT SWITCH LEARNING While the 5 LEDs are flashing give a Step by Step command the leaf 2 must move first performing a closure when it reaches ...

Page 12: ...Address Via Sandro Pertini 3 5 31014 COLLE UMBERTO TV Italia Telephone 39 0438 388592 Telefax 39 0438 388593 http www homelife it e mail info homelife it ...

Reviews: