1    LINKS AND CONNECTIONS

1.1   Central Connections

Clamps 

 

Description ( check electical scheme , page 5)

1

  

ANTENNA: 

 

2

Antenna cable imput.

6

COMMON COMMANDS: 

6 - 7

 

STOP: 

Imput N.C. Commands the gate’s halt.

To this can be connected to safety devices such as an emergency arrest button.
When released the command does not do an automatic arrest , it is instead necessary to give a new
movement command. Leave the bridge in place if no devices are installed.

6 - 8

OPEN: 

Imput N.O. Commands the opening of the gate.

6 - 9

 

CLOSE : 

Imput N.O. Commands the gate’s halt.

6 - 10

 

SETP-BY-STEP: 

Imput N.O. Command the gate’s actions following this commands :

SEMI-AUTOMATIC MODE : Open ,Stop,Close,Stop

FOUR STEPS MODE : Open,Pause,Close,Pause. 

  

CONDOMINIUM MODE : Open (automatic closing with the active pause time).

6 - 11

PHOTO: 

  Imput N.C for photocells and safety devices . While the gate is opening doesn’t intervene ,

12 - 13

RELE’ CONTACT :  

14 - 16

ELECTIC LOCK: 

 

   

Exit 12Vdc for the connection with the electric lock at 12Vdc 15VA; in order to activate 

 

 

15 - 16

 

Exit 24 Vdc 25W max to connect the blinker

16

+

17

-

N.C. = contact normally closed - N.O = contact normally open

The command determines the opening of only one side. Can be given by remote or clamps  

When using the terminal block a bridge will be obtained and the clamp n°8 will be OPEN , the clamp n°9 will CLOSE
this bridge will be connected to a switch at clamp n°6 common. The command PEDESTRIAN from terminl block 
won’t have the OPEN and CLOSE commands.

EXIT 30 Vdc : 

To power various devices, max 200mA.

CONN-1

 

24Vac:

 

Input transformer power 

 

33 - 34 

Engine 2, if closed opens second.

 

 

Engine 1, if closed opens first.

PHOTO1: With option 1 Led 4 , the imput becomes N.C. in order to connect the photocell that 

                 

acts while in the Closing and Opening phase.

 

Clean contact Relè Max 3A , default for the connection to an open gate LED 

 With the activation OPTION 2 Led 2 becomes a command for the courtesy light timed at 3 minutes.

- / + 

35 - 36 

- / + 

-  Before proceeding with the links and connections carefully read what is presented in the PRESCRIPTIONS AND 
   WARNINGS FOR SECURITY and PRESCRIPTIONS AND WARNINGS FOR THE INSTALLATION.
-  All of the linking and connecting operations must be performed with the power source disconnected , if the device is not 
   visible a sign must be applied : “ WARNING UNDER MAINTENANCE ”.
    

Stocking antenna input , use RG58-50 Ohm cable.

ANTENNA: 

For the imputs:  STOP - OPEN - CLOSE - STEP BY STEP - PHOTO.

BLINKER: 

PEDESTRIAN: 

Connections bottom of the control unit 

CONN-2

Connection battery charger AGECH-2 

while closing it dertermines the inversion of the motion until the complete opening.
Leave the bridge open if no devices are installed.

select the function from the Options meù n°1 Led n°3

Safety devices such as an emergency stop button can be connected to it.
When the command is released, automatic closing is never carried out but a new movement command 
must be given. Leave the jumper if no device is provided.

input

Input

Input

Input

PHOTO1: With OPTION 1 Led 4, the input becomes N.C. for the connection of a photocell that intervenes 
in Opening and Closing.

Input N.O. Controls the movement of the gate according to the following cycles:

FOUR STEPS MODE: Open, Pause, Close, Pause.
SEMI-AUTOMATIC MODE: Open, Stop, Close, Stop.
CONDOMINIUM MODE: Opens (automatic closure with active pause time).

PHOTO: N.C. input for photocells or safety devices. During the opening of the gate it does not intervene; in 
closing it causes the inversion of the movement until the complete opening.
Leave the jumper if no device is provided.

PHOTO

RELAY CONTACT: Dry contact Relay Max 3A, default for the connection of an Open gate light. With the 
activation of OPTION 2 Led 2 becomes a command for the courtesy light timed at 3 minutes.

RELAY CONTACT

ELECTRIC LOCK: 12Vdc output for connection of 12Vdc 15VA electric lock; to activate it, select the function 
from the Options menu 1 Led 3.

ELECTRIC LOCK

FLASHING: 24 Vdc 25 W max output, for connection of the flashing lamp.

FLASHING

PEDESTRIAN: The command causes an opening of only one leaf. It can be given by a remote control or by terminal board.
This terminal is obtained by bridging terminal 8 OPEN with terminal 9 CLOSE, this jumper then connects with a switch to 
terminal 6 COMMON. The PEDESTRIAN command from the terminal board excludes the OPEN and CLOSE commands.

PEDESTRIAN

input

inputs

electrical

Summary of Contents for CT2 24 UNI DL

Page 1: ...Rev 01 26 2018 LG CT2 24 UNI DL 24V F CONTROL UNIT FOR TWO LEAF GATES INSTRUCTIONS AND WARNINGS FOR INSTALLATION USE AND MAINTENANCE GB ...

Page 2: ... manufacturer its maintenance Important safety instructions For personal safety it is important to follow these instructions Keep these instructions The device must be disconnected from the power supply during cleaning and maintenance operations and the replacement of components Do not allow children to play with the gate control devices Keep remote controls away from children Monitor the moving g...

Page 3: ...3 mm 250 mm 184 min cm 40 5 3 4 1 2 GEBOX ASSEMBLY INSTRUCTIONS ...

Page 4: ...ESCRIPTIONS AND WARNINGS FOR SECURITY and PRESCRIPTIONS AND WARNINGS FOR THE INSTALLATION All of the linking and connecting operations must be performed with the power source disconnected if the device is not visible a sign must be applied WARNING UNDER MAINTENANCE Stocking antenna input use RG58 50 Ohm cable ANTENNA For the imputs STOP OPEN CLOSE STEP BY STEP PHOTO BLINKER PEDESTRIAN Connections ...

Page 5: ...der the terminal block show the entry state L7 and L11 are imputs N C and must be turned on they turn off when the corresponding imput is activated L8 L9 L10 are imputs N O must be turned off and they will automatically turn on when the corresponding imput is activated COMMON COMMANDS Relay PEDESTRIAN SIGNALING LED The LEDs under the terminal block indicate the state of the entrance L7 and L11 are...

Page 6: ...press and keep pushed the button release after the central unit 2 CENTRAL UNIT PROGRAMMATION 2 1 TOTAL RESET ATTENTION START START START START To optimize energy consumption we have introduced the Energy Saving function After 10 minutes from the control unit setup the front panel LEDs turn off and the use of the keyboard is inhibited To reactivate it it is necessary to switch the control unit off ...

Page 7: ...e control unit is fitted with a built in radio receiver with a 750 code memory and 2 channels with a 433 92 MHz frequency with LIFE Rolling Code and Auto code encoding Press the key fob selection button top left the left green LED under symbol and the first red dot A beside symbol will light up Hold down the P1 button on the transmitter that you want to pair to perform a total opening until all fi...

Page 8: ...E CLOSE PAUSE MINIMUM 4 3 ADJUSTMENT TIME OF DECELERATION a Press the for 5 the Led green and red on the right will turn on ATTENTION The deceleration CAN T be completely eliminated in this phase the limit switch s push force will determine the Stop in the motor s run By pressing and you can adjust the value of he DECELERATION TIME MAXIMUM DEFAULT LEDS ON LEDS ON PAUSE TIME DECELERATION TIME CHIUS...

Page 9: ...IMIUM DEFAULT LED ON SPEED MINIMUM 75 a Press the button and left red led will turn on By pressing or the speed can be adjusted MAXIMUM 100 DEFAULT 90 LED ON ATTENTION Based on the gate s structure and on its usage parameters such as sensitivity and speed mus be setted accordingly to the laws of the country By pressing or the sensitivity can be adjusted Wait 20 or press the button again to anticip...

Page 10: ...interventions during movement Funcioning with PRESENT MAN Wait for 20 or press the again to exit programming mode No active function Wait for 20 or press the again to exit programming mode button to enter the OPTION MENU 1 then press it again in sequence to scroll through the available options The flashing LEDS indicate the position and the corresponding option By pressing button the function is a...

Page 11: ...rogramming can be done with a button connected to terminals 6 10 Step by Step or with the previously memorized radio control page 7 chap 3 1 Place the motors leaves at 45 Hold the START button for 5 seconds the 5 LEDs first light up and then flash CLOSING LIMIT SWITCH LEARNING While the 5 LEDs are flashing give a Step by Step command the leaf 2 must move first performing a closure when it reaches ...

Page 12: ...Address Via Sandro Pertini 3 5 31014 COLLE UMBERTO TV Italia Telephone 39 0438 388592 Telefax 39 0438 388593 http www homelife it e mail info homelife it ...

Reviews: