Lifecycle 9500RHR Series Exercise Bikes
TROUBLESHOOTING GUIDE
15
Symptom: Battery Over-Heating
Symptom
Probable Cause
Corrective Action
Battery over-heating during
exercise program.
Battery Wires incorrectly
connected
Inspect connections: red wire to positive (+)
lead; black wire to negative (-) lead.
Worn Battery Wires
Inspect Wires. Replace Wires or harness.
Battery leads grounding upon
frame
Inspect leads. Replace battery.
Malfunctioning Display Console
Test with substitute Display Console. Replace
malfunctioning Display Console.
Malfunctioning Alternator
Control Board
Test with substitute Alternator Control Board.
Replace defective board.
For Assistance Contact
Life Fitness Customer Support Services
Teleph.: 847.451.0036 or 800.351.3737
Telefacs.: 847.288.3702 or 800.216.8893