Lifecycle 9500RHR Series Exercise Bikes
TROUBLESHOOTING GUIDE
2
Symptom: No Power
Symptom
Probable Cause
Corrective Action
Display Console LEDs do
not illuminate
Pedaling too slowly
Pedal faster than 45 RPM then press the
START button.
Keypad not responding
Massage keypad with fingertips.
Insufficient battery voltage
Test the battery voltage.
It should be:
5.8 to 6.3 VDC. If necessary, replace the
battery with a fully charged 6V battery.
Loose wire connections
Disconnect then reconnect connections.
Worn or damaged wire
harnesses.
Inspect wire harnesses. Replace worn or
damaged harness.
Malfunctioning Display Console
Test with substitute Display Console. Replace
malfunctioning Display Console.
Malfunctioning Alternator
Control Board (ACB)
Test with substitute ACB. Replace
malfunctioning ACB.
Malfunctioning Alternator
Test Alternator output or test with substitute
Alternator. Replace malfunctioning Alternator.
Refer to Alternator Voltage Test.
For Assistance Contact:
Life Fitness Customer Support Services
847.451.0036 or 800.351.3737
Telefacs.: 847.288.3702 or 800.216.8893