P34 TILT-axis loading position
At this point, the TILT axis
loading position
can be adjusted.
It is the position for
mounting
or
dismounting
the load.
It is very important for mounting or dismounting have the motoryoke on the
right
position.
Otherwise it is
not
possible to assemble the load. Especially, when
no
DMX is available.
Normally it is the
same
as the TILT axis 0° position, see
P06 TILT axis 0° position, page
23
.
Range of values:
2000..2100 units (value of the absolute value device)
Recommended value:
2048 (value of the absolute value device)
Operation:
depress You are now on menu level. The last adjusted menu
point is displayed, e.g.:
Menu P01:
DMX address motoryoke
depress ... until Menu P34 is displayed.
depress The second line displays the currently adjusted value.
depress Adjust the desired value, rotation is moving to this position
Wait until TILT is
not moving
anymore.
Adjust the desired position
depress You are back on menu level.
depress The equipment is ready for operation.