Part 4 Trouble Shooting
- 63 -
Copyright © 2019 - 2020 LG Electronics Inc.
All rights reserved. Only training and service purposes.
6.6 Troubleshooting Indoor Error
CH 01 (Indoor unit air sensor error)
CH 02 (Indoor unit pipe inlet sensor error)
CH 06 (Indoor unit pipe outlet sensor error)
** In case the value is more than 100 kΩ (open) or less than 100 Ω (short), Error occurs
Refer: Resistance value maybe change according to temperature of temp sensor,
It shows according to criteria of current temperature(±5 % margin) Normal
Air temp sensor: 10 °C = 20.7 kΩ : 25 °C= 10 kΩ : 50 °C= 3.4 kΩ
Pipe temp sensor: 10 °C = 10 kΩ : 25 °C= 5 kΩ : 50 °C= 1.8 kΩ
Is sensor properly
connected to PCB?
Is the resistance value
of sensor normal?*
Connect properly to PCB
Change the sensor
Change the PCB
Yes
Yes
No
No
CN_PIPE_IN : Pipe inlet temp sensor
CN_PIPE_OUT : Pipe outlet temp sensor
CN_ROOM : Indoor air temp sensor
Measure the resistance of outlet pipe temp sensor.
Error No.
Error Type
Error Point
Main Reasons
01
Indoor unit air sensor error
Indoor unit sensor is open/
short
1. Indoor unit PCB wrong connection
2. Indoor unit PCB failure
3. Sensor problem (main reason)
02
Indoor unit pipe inlet sensor error
06
Indoor unit pipe outlet sensor error
■
Error diagnosis and countermeasure flow chart