
105
ACCESSORIES INSTALLATION
ENGLISH
How to Wire 2nd Circuit (For Hydrosplit)
Follow below procedures Step 1 ~ Step 2.
Step 1. Uncover front cover of the unit.
Step 2. Find terminal block and connect wire as below
(L)
(N)
(L1) (L2) (N1)
MIX
PUMP
MIXING VALVE
L
N
L1
L2
13
14
15
16
N
17
MIX
PUMP
MIXING VALVE
(L) : Live signal from PCB to mix pump
(N) : Neutral signal from PCB to mix pump
(L1) : Live signal (for Normal* Closed type) from PCB to
mixing valve
(L2) : Live signal (for Normal Open type) from PCB to mixing
valve
(N1) : Neutral signal from PCB to mixing valve
*Closed = NOT Mixed
Step3. Insert the temperature sensor to 'CN_MIX_OUT' (Brown) of the main PCB as shown
below. The sensor should be mounted correctly to outlet pipe of mix kit water pump as
shown below.
CN_MIX_OUT
Indoor PCB
[Circuit 1] Direct Circuit
Radiator
Radiator
Buffer
Tank
Hydronic
separator
Floor
heating loop
Floor
heating loop
2
nd
circuit temp. sensor
Mix
Mix Kit
[Circuit 2] Mixing Circuit
NOTE
Temperature sensor specification:
Type : Thermistor,NTC
Resistance at 25 °C : 5 k
Ω
Minimum operating temperature range : -30 °C~100 °C
Summary of Contents for THERMA V
Page 276: ...276 ENGLISH ...