- 92 -
Valve Service (3-way)
3-way Valve (Liguid Side)
3-way Valve (Gas Side)
Works
Shaft position
Shaft position
Service port
Shipping
Closed
Closed
Closed
(with valve cap)
(with valve cap)
(with cap)
Air purging
Open
Closed
Open
(Installation)
(counter-clockwise)
(clockwise)
(push-pin or with
vacuum pump)
Operation
Open
Open
Closed
(with valve cap)
(with valve cap)
(with cap)
Pumping down
Closed
Open
Open
(Transfering)
(clockwise)
(counter-clockwise)
(connected
manifold gauge)
Evacuation
Open
Open
Open
(Servicing)
(connected
manifold gauge)
Gas charging
Open
Open
Open
(Servicing)
(with charging
cylinder)
Pressure check
Open
Open
Open
(Servicing)
(connected
manifold gauge)
Gas releasing
Open
Open
Open
(Servicing)
(connected
manifold gauge)
3.
2.
1.
4.
5.
6.
Valve cap
Open position
Closed position
Pin
Service
port
Service
port cap
To piping
connection
To outdoor unit
Valve cap
Open position
Closed position
Pin
Service
port
Service
port cap
To outdoor unit
To piping
connection
Service port
Closed
(with cap)
Open
(push-pin or with
vacuum pump)
Closed
(with cap)
Closed
(with cap)
Closed
(with cap)
Open
(connected
manifold gauge)
Open
(connected
manifold gauge)
Open
(connected
manifold gauge)
Summary of Contents for HPCI-C35E
Page 110: ... 110 Electronic Control Device 1 Room Type Indoor Unit MAIN P C B DC ASM MAIN P C B AC ASM ...
Page 111: ... 111 2 Cassette Type Indoor Unit MAIN P C B DC ASM ...
Page 112: ... 112 3 Convertible Type Indoor Unit ...
Page 113: ...4 Duct Type Indoor Unit 9 12k 113 ...
Page 114: ... 114 18k ...
Page 115: ... 115 5 Display ASSY Room Type Indoor Unit Convertible Type Indoor Unit ...
Page 116: ... 116 6 Outdoor Unit MAIN P C B ASM V P U N W ...
Page 117: ... 117 Schematic Diagram 1 Room Type Indoor Unit ...
Page 119: ... 119 3 Convertible Type Indoor Unit RY 4WAY RY OUTFAN ...
Page 139: ...P No 3828A20097S February 2004 Printed in Korea ...