145
INSTALLER SETTING
ENGLISH
DHW time setting
Determine following time duration : operation time of DHW tank heating, stop time of DHW tank
heating, and delay time of DHW tank heater operating.
- Active time : This time duration defines how long time DHW tank heating can be continued.
- Stop time : This time duration defines how long time DHW tank heating can be stopped. It is
also regarded as time gap between DHW tank heating cycle.
- Electric heater delay time : This time duration defines how long time electric heater will not be
turned on in DHW heating operation. The electric heater delay time setting can be set in the
‘Use Heating Tank Heater’ cartegory.
- Example of timing chart :
DHW tank
heating is enabled
DHW tank heater
is enabled
DHW tank
heating operation
DHW tank
heater operation
1=active / 0=not active
A = Active time
S = Stop time
E = Electric heater delay time
Time
E
E
A
S
S
S
1
0
1
0
1
0
1
0
❈
❈
❈
❈
OK
OK
Value
Default
Range
Active time
30 min
5~95 min
Stop time
30 min
0~600 min