SAFETY INSTRUCTIONS
ENGLISH
• The appliance shall be stored so as to prevent mechanical
damage from occurring.
• Servicing shall only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel shall be carried out under
the supervision of the person competent in the use of flammable
refrigerants.)
• When mechanical connectors are reused indoors, sealing parts
shall be renewed. When flared joints are reused indoors, the
flare part shall be re-fabricated.
• Periodic(more than once/year) cleaning of the dust or salt
particles stuck on the heat exchangers by using water.
• Keep any required ventilation openings clear of obstruction.
CAUTION
Installation
• Always check for gas (refrigerant) leakage after installation or
repair of unit.
- Low refrigerant levels may cause failure of unit.
• Keep level even when installing the unit.
- To avoid vibration or water leakage.
• Use two or more people to lift and transport the unit.
- Avoid personal injury.
• In order to avoid a hazard due to inadvertent resetting of the
thermal cut-out, this appliance must not be supplied through
an external switching device, such as a timer, or connected to
a circuit that is regularly switched on and off by the utility.
• Do not install the unit in potentially explosive atmospheres.
• The water may drip from the discharge pipe of the pressure-
relief device and that this pipe must be left open to the
atmosphere.
• The pressure-relief device is to be operated regularly to
remove lime deposits and to verify that it is not blocked.
• A discharge pipe connected to the pressure-relief device is to
be installed in a continuously downward direction and in a
frost-free environment.
!