11. AUTO CALIBRATION
11.4 AGC
This procedure is for Rx calibration.
In this procedure, We can get RSSI correction value. Set band EGSM and press Start button the
result window will show correction values per every power level and gain code and the same
measure is performed per every frequency.
11.5 APC
This procedure is for Txcalibration.
In this procedure you can get proper scale factor value and measured power level.
11.6 ADC
This procedure is for battery calibration.
You can get main Battery Config Table and temperature Config Table
11.7 Setting
check com port and cable loss. Select automatic calibration item.
If you uncheck one item calibration will stop from the unchecked item.
This is useful when you want to process only oneitem.
11.8 How to do calibration
A. Connect cable between phone and serial port of PC.
B. Connect Ag8960 equipment and Power Supply and phone.
C. Set correct port and baud rate.
D. Press Start button. AutoCal process all calibration procedure
i. AGC EGSM
ii. AGC DCS
iii. APC EGSM
iv. APC DCS
v. ADC
E. After finished all measurement. The state is return to SETUP.
F. The Cal file will be generated and then the calibration data will be written into phone and then
will be reset.
- 119 -
Summary of Contents for B2070
Page 68: ... 67 4 TROUBLE SHOOTING TEST POINT 4 6 LCD Trouble ...
Page 72: ... 71 4 TROUBLE SHOOTING TEST POINT 4 8 Speaker Trouble ...
Page 79: ... 78 4 TROUBLE SHOOTING 4 11 KEY backlight Trouble TEST POINT ...
Page 107: ... 106 8 PCB LAYOUT Figure 8 1 B2070 BOTTOM SIDE PCB LAYOUT ...
Page 108: ... 107 8 PCB LAYOUT Figure 8 1 B2070 TOP SIDE PCB LAYOUT ...
Page 109: ... 108 ...
Page 117: ...10 STAND ALONE TEST 116 Figure 10 2 HW test setting Figure 10 3 Ramping profile ...
Page 121: ... 120 ...
Page 123: ... 122 ...