4. Trouble Shooting
- 67 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
6.6 Troubleshooting Indoor Error
CH 01 (Indoor unit air sensor error
CH 02 (Indoor unit pipe inlet sensor error
CH 06 (Indoor unit pipe outlet sensor error)
** In case the value is more than 100kΩ (open) or less than 100Ω (short), Error occurs
Refer: Resistance value maybe change according to temperature of temp sensor,
It shows according to criteria of current temperature(±5% margin)
Normal
Air temp sensor: 10°C = 20.7kΩ : 25°C= 10kΩ : 50°C= 3.4kΩ
Pipe temp sensor: 10°C = 10kΩ : 25°C= 5kΩ : 50°C= 1.8kΩ
Is sensor properly
connected to PCB?
Is the resistance value
of sensor normal?*
Connect properly to PCB
Change the sensor
Change the PCB
Yes
Yes
No
No
CN-ROOM : Indoor air temp sensor
CN-PIPE IN : Pipe inlet temp sensor
CN-PIPE OUT : Pipe outlet temp sensor
Measure the resistance of outlet pipe temp sensor.
&SSPS/P
&SSPS5ZQF
&SSPS1PJOU
.BJO3FBTPOT
*OEPPSVOJUBJSTFOTPSFSSPS
*OEPPSVOJUTFOTPSJTPQFO
TIPSU
*OEPPSVOJU1$#XSPOHDPOOFDUJPO
*OEPPSVOJU1$#GBJMVSF
4FOTPSQSPCMFN NBJOSFBTPO
*OEPPSVOJUQJQFJOMFUTFOTPSFSSPS
*OEPPSVOJUQJQFPVUMFUTFOTPSFSSPS
&SSPSEJBHOPTJTBOEDPVOUFSNFBTVSFGMPXDIBSU