4. Trouble Shooting
Items
Contents
Purpose
Protection of IPM and compressor in the PCB assembly from over-
current.
Condition for Generation Increased compressor current exceeding the standard.
Expected
Causes
Installation &
Overload
Transfer of signals with detection of the flow of over-current in PSC/PFC,
blocking of a outdoor unit.
Compressor
Open/Short of the coil in the compressor, insulation breaking between
the coil in the compressor and the sash, damage of compressor with
abrasion, and compressor connection fault
PCB
Assembly
Compressor current detection circuit fault, DC link detection circuit fault,
and fault of single unit of IPM
Others
Input of abnormal power and power connection fault