background image

Wiring Diagrams

Service Manual  51

Heat Pump : AUUH186AB/AUUH246AB/AUUH306AB

Heat Pump : AUUH368AB/AUUH488AB/AUUH608AB

3854A20125S

1(L)

POWER
SUPPLY

220-240V~
50Hz

TMo

BR

BR

BL

GN/YL

PR

FMo

TMi

COMP

OUTDOOR WIRING DIAGRAM

D-PWB

Co

C

S

R

Co

BL

GN/YL

BR

RD

BL

2

4

6

0

1

8

BL

RD

RD

BL

FUSE(250V,5A)

FUSE(250V,5A)

BL

WH

BR

TH

BK

BK

BK

BK

BK

OR

WH

TB1

TB2

TH

L4

NC NO

NCNO

L3 L1

L2

TRANS

NOTE

RD:RED
WH:WHITE
YL:YELLOW
BL:BLUE
BK:BLACK
BR:BROWN
OR:ORANGE
GN/YL:GREEN/YELLOW

FMo

Co

PR

TB

TMo

TMi

TH

D.PWB

LAC

OUTDOOR FAN MOTOR

CAPACITOR

POWER RELAY

TERMINAL BLOCK

MAIN TERMINAL BLOCK

TERMINAL BLOCK

THERMISTOR

DEICER PWB

LOW AMBINENT PWB

T

O

 INDOOR UNIT

OR

YL

2(N)

8

7

6

5

4(N)

3(L)

WIRING OF FIELD
(CONNECTOR WIRING)

PR

4WV

1

2

3

4

5

6

7

8

9

LAC

FUSE  

T3.15A

TRIAC

Outdoor  Unit  Wiring  Diagram

R

POWER SUPPLY

MAGNETIC

CONTACTER

CRANK-CASE
HEATER

S T N

BK

BK

BK

BK

BK

WH

WH

WH

WH

RD

BK

BL

WH

D.P

TNS

NO

NO

pipe TH

NC

NC

WH

OR

WH

BK

BK

OR

BK

BK

BK

WH

POWER

RELAY

1

2

3

4

5

6

21

T/B3

T/B2

T/B1

22

A2

A1

FAN

MOTOR

FAN

MOTOR

YL BK

OR

BK

(U)

T3

(V)

T2

(W)

T1

RD

BK

WH

COMP.

1

2

3

4

5

6

7

8

YL BK

OR

OR

BK

BK

BL

BL

BK

BK

BK

WH

CAPACITOR

CAPACITOR

REVERSING

VALVE

GN/YL

TERMINAL BLOCK

To

  the  indoor  unit

1

2

3

4
5

6

7

8

9

BK

WH

WH

BL

Fuse

(250V 5A)

Fuse

(250V 5A)

BK

P/NO : 3854A24003B

BK

BK

PIPE TH

Low Ambient PCB

REMOVE JUMP WIRE
WHEN CONNECTING
FIRE ALARM SYSTEM

FUSE  T3.15A

TRIA

C

1(L)

2(N)

3

4
5

6

Summary of Contents for ABNC186HLAA

Page 1: ...ir Conditioner SERVICE MANUAL LG CAUTION website http www lgservice com e mail http www lgeservice com techsup html BEFORE SERVICING THE UNIT READ THE SAFETY PRECAUTIONS IN THIS MANUAL ONLY FOR AUTHORIZED SERVICE PERSONNEL ...

Page 2: ...s 9 5 List of Functions 13 6 Function of Remote Control 16 7 Specifications 21 8 Dimensional Drawings 33 9 Wiring Diagrams 43 10 Refrigerant Cycle Diagrams 52 11 Electrical Data 54 12 Operation Range 55 13 External Static Pressure Air flow 56 14 Installation 60 15 Electronic Control Device 78 16 Schematic Diagram 81 17 Exploded View and Replacement Parts List 85 ...

Page 3: ...C608DLAA 17 6 60K Ceiling Cassette ATNC608DLCA AUUC608A AB Ceiling Concealed Duct ABNC608ELAA 1 1 Cooling Only Ceiling Cassette ATNH186ELAA Ceiling Cassette ATNH186ELCA 5 3 18k Ceiling Concealed Duct ABNH186HLAA AUUH186A AB Ceiling Floor AVNH186BLAA Ceiling Cassette ATNH246FLAA Ceiling Cassette ATNH246FLCA 7 0 24k Ceiling Concealed Duct ABNH246HLAA AUUH246A AB 1Ø 220 240V 50Hz Ceiling Floor AVNH24...

Page 4: ... ATN Universal Ceiling Cassette Type Indoor Unit ABN Universal Ceiling Concealed Duct Type Indoor Unit AVN Universal Ceiling Floor Type Indoor Unit A U U H 1 8 6 A Serial Number Low Ambinent Optional Electric Standard Phase Volts Freq 6 1Ø 220 240V 50Hz 8 3 Ø 380 415V 50Hz Nominal Cooling Capacity in Btu h Model Type C Cooling Only H Heat Pump R410A Universal Outdoor Unit B P T H E A Functions A B...

Page 5: ...ry or damage to properties only Installation Be sure not to do Be sure to follow the instruction Do not use a defective or under rated circuit breaker Use this appliance on a dedicated circuit There is risk of fire or electric shock Always ground the product There is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire or electric shock Alway...

Page 6: ...tive installation stand It may cause injury accident or damage to the product Be sure the installation area does not deteriorate with age If the base collapses the air condi tioner could fall with it causing property damage product failure and personal injury Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open Moisture may condense ...

Page 7: ...roduct damage Always check for gas refrigerant leakage after installation or repair of product Low refrigerant levels may cause failure of product Install the drain hose to ensure that water is drained away properly A bad connection may cause water leakage Do not store or use flammable gas or com bustibles near the product There is risk of fire or failure of product If strange sounds or small or s...

Page 8: ...fire electric shock or damage to the plastic parts of the product Do not touch the metal parts of the product when removing the air filter They are very sharp There is risk of personal injury Do not step on or put anyting on the product outdoor units There is risk of personal injury and failure of product Do not insert hands or other objects through the air inlet or outlet while the product is ope...

Page 9: ...ic diseases like asthma It provides odor free dust free and allergy free air Group Control It enables to control as much as 16 units with the help of one wired remote controller All the units will follow same setting of temperature other sub func tions Central Control It enables to control 16 x 8 128 units with the help of 8 controllers All units can be put on and off from one Central Room For Set...

Page 10: ...er there is electricity failure to the unit and after resumption of the power unit will start in the same mode prior to the power failure Memorized condition are on off condition operating mode cooling heating set temperature and fan speed The unit will memorize the above conditions and start with same memorized condition Two Thermistor Control There may be a significant difference between the tem...

Page 11: ... you can adjust high rpm of indoor fan motor Selection of speed can be done by slide switch at the back of the LCD wired remote ex Water Drain Pump In some of the places natural drainage is not possi ble For such places drain pump is very useful It removes condensed water from the unit Time Delay Safety Function It delays restarting of the compressor by three min utes thereby preventing damage to ...

Page 12: ...oduct E S P is controlled from 8 10mm Aq linearly E S P con trol provides required constant air volume irrespec tive of ESP change Desired ESP can also be set through LCD wired remote Setting of the desired ESP gives required combination of ESP and air flow Electric Heater Electric Heater can be used to provide heat in addition to cycle heat It also provide quick heat ing It can also work as a sta...

Page 13: ...frigerant o o o o o o Fire Alarm Function Forced Operation o o o o o o Group Control o o o o o o High Ceiling Operation o o o o o o Hot Start o o o Jet Cool o o o o o o Low Ambient Control Optional Optional Optional Optional Optional Optional Plasma Air Purifier Optional Optional Optional Optional Optional Optional Prefilter Washable Anti fungus o o o o o o Restart Delay 3 minutes o o o o o o Self...

Page 14: ...r weekly Two Thermistor Control Space Control Wired LCD Remote Controller Wireless Remote Controller Zero Standby Power Zone Control ABNC HL ABNC GL ABNC EL ABNH HL ABNH GL ABNH EL Notes O Basic Optional Factory Installed Accessory Field Installed Not available on this system 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 o o o o o o o o o o o o o o o Accessory Accessory Accessory Accessory Accessory Accessory o o...

Page 15: ...nction Forced Operation Group Control High Ceiling Operation Hot Start Jet Cool Low Ambient Control Plasma Air Purifier Prefilter Washable Anti fungus Restart Delay 3 minutes Self Diagnosis Sleep Mode Soft Dry Operation Swirl Swing Tele Control Temperature Control Test Function Time Delay Safety function Timer weekly Two Thermistor Control Space Control Wired LCD Remote Controller Wireless Remote ...

Page 16: ...ooling operates super high fan speed in cooling mode 6 CHAOS AUTO SWING BUTTON Used to stop or start louver movement and set the desired up down airflow direction 7 ON OFF TIMER BUTTONS Used to set the time of starting and stopping opera tion 8 TIME SETTING BUTTONS Used to adjust the time 9 TIMER SET CANCEL BUTTONS Used to set the timer when the desired time is obtained and to cancel the Timer ope...

Page 17: ...o swing up and down 8 SLEEP MODE BUTTON Used to set Sleep Mode Auto operation 9 AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating turns indoor fan on off 10 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature 11 RESET BUTTON Used prior to resetting time or after replacing batteries 12 INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps lo...

Page 18: ... Button Used to set the timer when the desired time is obtained Then the wired remote controller is set up to 24 hours by an hour but the wireless remote controller is set up to 7 hours by an hour Therefore if you want to set over 7 hours use the wired remote controller 6 Fan Speed Button Used to set the desired fan speed 7 On Off Button Operation starts when this button is pressed and stops when ...

Page 19: ...o set the desired fan speed and select jet cool mode 6 Operation Mode Selection Button Used to select the operation mode Auto Operation Mode Cooling Operation Mode Soft Dry Operation Mode Heating Operation Mode except cooling model 7 Auto Swing Button Used to swing up and down 8 Room Temperature Checking Button Used to check the room temperature 9 Plasma Air Clean Button optional 10 Timer Cancel B...

Page 20: ...on Button Used to circulate room air without cooling or heat ing 5 Electric Heater Button optional Used to set the Electric Heater 6 Fan Speed Button Used to set desired fan speed 7 Operation Mode Selection Button Used to select the operation mode Auto Operation Mode Cooling Operation Mode Soft Dry Operation Mode Heating Operation Mode except cooling model 8 Timer Cancel Button Used to cancel the ...

Page 21: ...4 6 35 5 8 15 88 33 0 22 6 0 8 840 575 275 44 98 8 Outdoor Unit AUUC186A AB Locked Rotor Amp A Type Quantity No Model Maker Compressor Capacity W Btu h Motor Type Motor Input W Oil Type Oil Charge cc O L P Type Model Name Tube Size OD inch mm Outdoor Coil Fins per inch No of Rows Column Output W Model Outdoor fan motor No of Poles Input W Running Current A Capacitor µF Vac Type Outdoor Fan No Used...

Page 22: ...ize OD inch mm Outdoor Coil Fins per inch No of Rows Column Output W Model Outdoor fan motor No of Poles Input W Running Current A Capacitor µF Vac Type Outdoor Fan No Used Diameter EA inch mm Discharge Side Top Speed rpm Air Circulation Outdoor CMM CFM Noise Level Sound Press 1m Outdoor dB A 3 SVC Valve Liquid inch mm Gas Dimensions W H D Outdoor inch mm Net Weight Outdoor kg lbs Others Power Sup...

Page 23: ... 1m Outdoor dB A 3 SVC Valve Liquid inch mm Gas Dimensions W H D Outdoor inch mm Net Weight Outdoor kg lbs Others Power Supply Cable With Earth Cable No mm2 Conncecting Cable With Earth Cable Connecting Tube Liquid Side inch mm ø Socket Flare Gas Side inch mm Length std m Max length elevation m Drain hose ID ø Indoor Unit mm Outdoor Unit mm Notes 1 Capacities are based on the following conditions ...

Page 24: ...oor Fan No Used Diameter EA inch mm Discharge Side Top Speed rpm Air Circulation Outdoor CMM CFM Noise Level Sound Press 1m Outdoor dB A 3 SVC Valve Liquid inch mm Gas Dimensions W H D Outdoor inch mm Net Weight Outdoor kg lbs Others Power Supply Cable With Earth Cable No mm2 Conncecting Cable With Earth Cable Connecting Tube Liquid Side inch mm ø Socket Flare Gas Side inch mm Length std m Max len...

Page 25: ...ype Motor Input W Oil Type Oil Charge cc O L P Type Model Name Tube Size OD inch mm Outdoor Coil Fins per inch No of Rows Column Output W Model No of Poles Outdoor fan motor Input W Running Current A Capacitor µF Vac Type Outdoor Fan No Used Diameter EA inch mm Discharge Side Top Speed rpm Air Circulation Outdoor CMM CFM Noise Level Sound Press 1m Outdoor dB A 3 SVC Valve Liquid inch mm Gas Dimens...

Page 26: ... W Btu h Motor Type Motor Input W Oil Type Oil Charge cc O L P Type Model Name Tube Size OD inch mm Outdoor Coil Fins per inch No of Rows Column Output W Model Outdoor fan motor No of Poles Input W Running Current A Capacitor µF Vac Type Outdoor Fan No Used Diameter EA inch mm Discharge Side Top Speed rpm Air Circulation Outdoor CMM CFM Noise Level Sound Press 1m Outdoor dB A 3 SVC Valve Liquid in...

Page 27: ...utdoor Unit AUUH186A AB Locked Rotor Amp A Type Quantity No Model Maker Compressor Capacity W Btu h Motor Type Motor Input W Oil Type Oil Charge cc O L P Type Model Name Tube Size OD inch mm Outdoor Coil Fins per inch No of Rows Column Output W Model Outdoor fan motor No of Poles Input W Running Current A Capacitor µF Vac Type Outdoor Fan No Used Diameter EA inch mm Discharge Side Top Speed rpm Ai...

Page 28: ... Net Weight Indoor kg lbs Outdoor Unit AUUH246A AB Locked Rotor Amp A Type Quantity No Model Maker Compressor Capacity W Btu h Motor Type Motor Input W Oil Type Oil Charge cc O L P Type Model Name Tube Size OD inch mm Outdoor Coil Fins per inch No of Rows Column Output W Model Outdoor fan motor No of Poles Input W Running Current A Capacitor µF Vac Type Outdoor Fan No Used Diameter EA inch mm Disc...

Page 29: ...With Earth Cable Connecting Tube Liquid Side inch mm ø Socket Flare Gas Side inch mm Length std m Max length elevation m Drain hose ID ø Indoor Unit mm Outdoor Unit mm 124 OBM 4015P2 IC 13450LG13J IC 9430LGCL 6 4 4 146 300 81 0 67 1 34 0 36 4 440 6 370 1 5 370 Turbo Fan Sirocco Fan Cross Flow Fan 1 382 15 2 177 7 80 3 1 650 600 550 1415 1359 1290 1160 1060 960 650 600 550 1415 1359 1290 1160 1060 ...

Page 30: ...Valve Liquid inch mm Gas Dimensions W H D Outdoor inch mm Net Weight Outdoor kg lbs Others Power Supply Cable With Earth Cable No mm2 Conncecting Cable With Earth Cable Connecting Tube Liquid Side inch mm ø Socket Flare Gas Side inch mm Length std m Max length elevation m Drain hose ID ø Indoor Unit mm Outdoor Unit mm 52 5 272 IC 1630LGPJ IC 13450LG13A 6 4 175 323 0 76 1 42 4 450 6 370 Turbo Fan S...

Page 31: ...Outdoor fan motor No of Poles Input W Running Current A Capacitor µF Vac Type Outdoor Fan No Used Diameter EA inch mm Discharge Side Top Speed rpm Air Circulation Outdoor CMM CFM Noise Level Sound Press 1m Outdoor dB A 3 SVC Valve Liquid inch mm Gas Dimensions W H D Outdoor inch mm Net Weight Outdoor kg lbs Others Power Supply Cable With Earth Cable No mm2 Conncecting Cable With Earth Cable Connec...

Page 32: ...t W Model Outdoor fan motor No of Poles Input W Running Current A Capacitor µF Vac Type Outdoor Fan No Used Diameter EA inch mm Discharge Side Top Speed rpm Air Circulation Outdoor CMM CFM Noise Level Sound Press 1m Outdoor dB A 3 SVC Valve Liquid inch mm Gas Dimensions W H D Outdoor inch mm Net Weight Outdoor kg lbs Others Power Supply Cable With Earth Cable No mm2 Conncecting Cable With Earth Ca...

Page 33: ...e 570 Unit size 450 Hanging bolt 75 75 600 Ceiling opening 600 Ceiling opening 521 Hanging bolt 39 5 39 5 4 1 2 3 670 670 5 6 Ceiling Cassette Type Number Name Descripition 1 Liquid pipe connection Ø6 35 flare 2 Gas pipe connection Ø15 88 flare 3 Drain pipe connection 4 Power supply connection 5 Air discharge grill 6 Air suction grill unit mm Dimensional Drawings ...

Page 34: ...ze 744 Unit size 658 Hanging bolt 66 66 790 Ceiling opening 790 Ceiling opening 572 Hanging bolt 109 109 30 5 6 4 1 2 3 ATNC FL ATNH FL Ceiling Cassette Type Number Name Descripition 1 Liquid pipe connection Ø6 35 flare 2 Gas pipe connection Ø15 88 flare 3 Drain pipe connection 4 Power supply connection 5 Air discharge grill 6 Air suction grill unit mm ...

Page 35: ...5 101 5 875 Ceiling opening 875 Ceiling opening 785 Hanging bolt 45 45 Unit mm 4 1 2 3 950 950 5 6 Ceiling Cassette Type Number Name Descripition 1 Liquid pipe connection 36k Ø6 35 flare 48k Ø9 52 flare 60k Ø12 7 flare 2 Gas pipe connection 36k Ø15 88 flare 48k 60k Ø19 05 flare 3 Drain pipe connection 4 Power supply connection 5 Air discharge grill 6 Air suction grill unit mm ...

Page 36: ...2 50 172 Capacity A B 18K 24K 932 882 30K 36K 1232 1182 48K 60K 1292 1230 ABNC HL ABNC GL ABNC EL ABNH HL ABNH GL ABNH EL Top view unit mm Front view 600 H 600 Front Inspection hole 600X600 Control box 1000 l i h j k A H C D E F B G a b c d K J f e Suitable dimension H is necessary to get a slope to drain as figure Ø 15 88 Ø 6 35 18k 24k 30k 36k Ø 19 05 Ø 9 52 48k Ø 19 05 Ø 12 7 60k Gas Liquid Mod...

Page 37: ...ore than 20cm More than eye level More than 20cm R Ceiling installation R More than 20cm More than 20cm Floor Wall installation 250 36 36 1076 Rear Side 392 265 468 63 38 175 Installation Plate Unit mm 1076 Suspension bolt Center line for the piping hole 265 1236 265 1076 more than 260 265 1236 AVNC BL AVNH BL Ceiling Floor Type ...

Page 38: ...door Units Model No Dim W mm 840 H mm 575 D mm 275 L1 mm 305 L2 mm 31 L3 mm 317 L4 mm 558 L5 mm 17 L6 mm 610 L7 mm 640 L8 mm 55 L9 mm 175 L10 mm 145 L11 mm 70 L12 mm 63 L13 mm 54 AUUC186A AB Gas side 3 way valve Liquid side 3 way valve W L7 L10 L6 L8 L9 D L1 L2 L3 L13 L4 H L11 L10 L5 ...

Page 39: ...246A AB Model No Dim W mm 870 H mm 655 D mm 320 L1 mm 370 L2 mm 25 L3 mm 340 L4 mm 630 L5 mm 25 L6 mm 546 L7 mm 162 L8 mm 162 L9 mm 54 L10 mm 74 5 L11 mm 79 AUUH186A AB AUUC246A AB Gas side 3 way valve Liquid side 3 way valve W D L1 L2 L3 L6 L7 L8 L9 L4 H L11 L10 L5 ...

Page 40: ...A AB AUUH306A AB Model No Dim W mm 870 H mm 800 D mm 320 L1 mm 370 L2 mm 25 L3 mm 340 L4 mm 775 L5 mm 25 L6 mm 546 L7 mm 162 L8 mm 162 L9 mm 54 L10 mm 74 5 L11 mm 79 AUUH246A AB AUUC306A AB AUUH306A AB Gas side 3 way valve Liquid side 3 way valve W D L1 L2 L3 L6 L7 L8 L9 L4 H L11 L10 L5 ...

Page 41: ...No AUUC368A AB AUUH368A AB 74 5 4 holes for anchor bolts 79 320 64 160 160 550 1060 360 340 320 1030 870 4 2 3 1 Number Name Descripition 1 Liquid side service valve mm Ø6 35 2 Gas side service valve mm Ø15 88 3 Air discharge grill 4 Control Cover ...

Page 42: ...AB AUUH608A AB Model No Dim W mm 900 H mm 1 225 D mm 370 L1 mm 460 L2 mm 45 L3 mm 410 L4 mm 1 135 L5 mm 90 L6 mm 550 L7 mm 175 L8 mm 175 L9 mm 112 L10 mm 120 L11 mm 83 AUUC488A AB AUUH488A AB AUUC608A AB AUUH608A AB L6 L7 L8 L9 L4 H L11 L10 L5 W D L1 L2 L3 Gas side 3 way valve Liquid side 3 way valve ...

Page 43: ...STOR 1 Indoor Unit Ceiling Cassette Type Cooling Only ATNC EL FL Series Ceiling Cassette Type Cooling Only ATNC DL Series INDOOR WIRING DIAGRAM INDOOR MOTOR DRAIN PUMP PIPE THERMISTOR REMOTE CONTROL FLOAT S W CN DISP DISPLAY PCB OPTION AIR CLEANER H V ASSY DOOR S W TERMINAL BLOCK TO OUTDOOR UNIT 3854A22006D BR YL BK OR BL BL BL WH WH GN YL COMP RD BK WH RD BK 1 L 2 N 3 4 5 FUSE T3 15A STEP MOTOR S...

Page 44: ...OTOR STEP MOTOR TEMP THERMISTOR Ceiling Cassette Type Heat Pump ATNH EL FL Series Ceiling Cassette Type Heat Pump ATNH DL Series INDOOR WIRING DIAGRAM INDOOR MOTOR DRAIN PUMP PIPE THERMISTOR REMOTE CONTROL FLOAT S W CN DISP DISPLAY PCB OPTION AIR CLEANER H V ASSY DOOR S W TERMINAL BLOCK TO OUTDOOR UNIT 3854A22006C BR YL BK OR BL BL BL WH WH GN YL COMP RD BK WH RD BK 1 L 2 N 3 4 5 FUSE T3 15A STEP ...

Page 45: ... 3854A22006B TRIAC VENTILATOR T B GN YL Ceiling Concealed Duct Type Cooling Only ABNC HL GL Series Ceiling Concealed Duct Type Cooling Only ABNC EL Series INDOOR WIRING DIAGRAM INDOOR MOTOR DRAIN PUMP BR BR YL OR RD BL BL RD BL BL BK GN YL COMP FUSE 250V10A ROOM SENSOR PIPE SENSOR FLOAT S W REMOTE CONTROL ZONE CONTROL OPTION TERMINAL BLOCK 1 L 2 N 4 3 5 TO OUTDOOR UNIT 3854A20166L TELECONTROL CENT...

Page 46: ... OUTDOOR UNIT 3854A22006A TRIAC VENT OPTION GN YL Ceiling Concealed Duct Type Heat Pump ABNH HL GL Series Ceiling Concealed Duct Type Heat Pump ABNH EL Series Notes BR WH BL BROWN WHITE BLUE OR YL BK ORANGE YELLOW BLACK RD GN YL RED GREEN YELLOW INDOOR MOTOR DRAIN PUMP BR BR YL OR RD BL BL RD BK GN YL BL BL BK GN YL COMP 4WAY FUSE 250V10A ROOM SENSOR PIPE SENSOR FLOAT S W REMOTE CONTROL ZONE CONTR...

Page 47: ... DISP DOOR S W 1 2 4 3 RY M RY H TERMINAL BLOCK 3 L 4 N 5 6 7 STEP MOTOR 3854A22004A TO OUTDOOR UNIT INDOOR WIRING DIAGRAM 3854A20125N DISPLAY PCB ASSY TRANS FORMER THERMISTOR CN TH CN TRANS CN FAN RY L OR RD BL BK MOTOR CAPACITOR BR YL GN YL FUSE T3 15A STEP MOTOR RY COMP CN 4WAY RY 4WAY RY FAN CN UP DOWN 1 2 TO OUTDOOR UNIT GN YL BR BL WH BK CN DISP DOOR S W 1 4 3 RY M RY H TERMINAL BLOCK 3 L 4 ...

Page 48: ...RMINAL BLOCK THERMISTOR TO INDOOR UNIT OR YL 2 N 5 6 7 8 4 N TMi 3 L WIRING OF FIELD CONNECTOR WIRING PR C S R OUTDOOR WIRING DIAGRAM NOTE RD RED WH WHITE YL YELLOW BL BLUE BK BLACK BR BROWN OR ORANGE GN YL GREEN YELLOW FMo Co PR D PWB TB TMo TMi TH OUTDOOR FAN MOTOR CAPACITOR POWER RELAY DEICER PWB TERMINAL BLOCK MAIN TERMINAL BLOCK TERMINAL BLOCK THERMISTOR WIRING OF FIELD CONNECTOR WIRING R TMi...

Page 49: ... VALVE POWER RELAY DEICER PWB TERMINAL BLOCK MAIN TERMINAL BLOCK TERMINAL BLOCK THERMISTOR TO INDOOR UNIT OR YL 2 N 8 7 6 5 4 N 3 L WIRING OF FIELD CONNECTOR WIRING PR 4WV OUTDOOR WIRING DIAGRAM NOTE RD RED WH WHITE YL YELLOW BL BLUE BK BLACK BR BROWN OR ORANGE GN YL GREEN YELLOW FMo Co 4WV PR D PWB TB TMo TMi TH OUTDOOR FAN MOTOR CAPACITOR REVERSING VALVE POWER RELAY DEICER PWB TERMINAL BLOCK MAI...

Page 50: ...INAL BLOCK THERMISTOR LOW AMBINENT PWB TO INDOOR UNIT OR YL 2 N 5 6 7 8 4 N TMi 3 L WIRING OF FIELD CONNECTOR WIRING PR C S R TH 1 2 3 4 5 6 LAC FUSE T3 15A TRIAC 7 8 9 GN YL Outdoor Unit Wiring Diagram GN YL TMo To the indoor unit 2 N 1 L 3 4 5 3854A24003D F1 F1 R TM POWER SUPPLY S T N BK BK WH RD WH WH 52C 1 2 3 4 5 6 21 22 A2 A1 FMo 49FMo FMo 49FMo BK RD WH BK BL WH WH CM YL BK OR Co Co TB YL O...

Page 51: ...L BLOCK THERMISTOR DEICER PWB LOW AMBINENT PWB TO INDOOR UNIT OR YL 2 N 8 7 6 5 4 N 3 L WIRING OF FIELD CONNECTOR WIRING PR 4WV 1 2 3 4 5 6 7 8 9 LAC FUSE T3 15A TRIAC Outdoor Unit Wiring Diagram R POWER SUPPLY MAGNETIC CONTACTER CRANK CASE HEATER S T N BK BK BK BK BK WH WH WH WH RD BK BL WH D P TNS NO NO pipe TH NC NC WH OR WH BK BK OR BK BK BK WH POWER RELAY 1 2 3 4 5 6 21 T B3 T B2 T B1 22 A2 A...

Page 52: ...ELCA ABNC186HLAA AVNC186BLAA ATNC246FLAA ATNC246FLCA ABNC246HLAA AVNC246BLAA ATNC306FLAA ATNC306FLCA ABNC306GLAA AVNC306BLAA ATNC368DLAA ATNC368DLCA ABNC368GLAA ATNC488DLAA ATNC488DLCA ABNC488ELAA ATNC608DLAA ATNC608DLCA ABNC608ELAA Gas Liquid Rated Max Rated Max Pipe Size Diameter Ø inch Piping length m Elevation m Indoor Unit Additional Refrigerant g m 5 8 1 4 7 5 50 30 7 5 3 4 3 8 25 30 25 40 5...

Page 53: ...186ELAA ATNH186ELCA ABNH186HLAA AVNH186BLAA ATNH246FLAA ATNH246FLCA ABNH246HLAA AVNH246BLAA ATNH306FLAA ATNH306FLCA ABNH306GLAA AVNH306BLAA ATNH368DLAA ATNH368DLCA ABNH368GLAA ATNH488DLAA ATNH488DLCA ABNH488ELAA ATNH608DLAA ATNH608DLCA ABNH608ELAA Gas Liquid Rated Max Rated Max Pipe Size Diameter Ø inch Piping length m Elevation m Indoor Unit Additional Refrigerant g m 5 8 1 4 7 5 50 30 7 5 3 4 3 ...

Page 54: ...1 50 9 6 0 7 13 4 20 ABNH246HLAA 220 240 1 50 9 9 1 2 14 2 20 AVNH246BLAA 220 240 1 50 10 1 0 4 13 7 20 ATNC306FLAA AUUC306A AB 220 240 1 50 11 4 68 0 9 0 7 15 8 25 ATNC306FLCA 220 240 1 50 11 4 0 9 15 8 25 ABNC306GLAA 220 240 1 50 11 9 1 7 17 3 25 AVNC306BLAA 220 240 1 50 12 1 0 5 16 3 25 ATNH306FLAA AUUH306A AB 220 240 1 50 11 8 68 0 9 0 7 16 3 25 ATNH306FLCA 220 240 1 50 11 8 0 9 16 3 25 ABNH30...

Page 55: ...ient kit Indoor air temperature C D B F Standard operation Outdoor air temperature C W B F 18 64 4 10 50 24 75 2 10 14 Item Inlet air temperature Cooling Inlet air temperature Heating Note If the ambient temperature goes below 5 C 41 F the capacity drops down even if the low ambient kit is installed Power Source Voltage Rating 10 Voltage at Starting Min 85 of rating Range Operation Range ...

Page 56: ...ange the connection of the indoor fan motor connector to increase the motor speed to obtain similar CFM at 15 mmAq Static Pressure as at 10 mmAq Static pressure Static Pressure mmAq 0 2 4 6 8 10 15 Model Name Step CMM CFM CMM CFM CMM CFM CMM CFM CMM CFM CMM CFM CCMM CFM High 48 5 1 722 46 5 1 642 45 1 598 43 5 1 544 42 1 491 40 1 420 40 1 420 Med 43 1 527 41 5 1 466 39 5 1 402 38 1 349 36 5 1 296 ...

Page 57: ...Position F H Maximum E S P setting Fan speed doesn t vary according to the opening Closing of dampers 3 Position V L Minimum E S P setting Fan speed is varied according to the state of dampers by micom Maximum 18 24K 8mmAq 30 36K 10mmAq Minimum All 0mmAq 3 Move the slide switch to set position 4 Close the rear cover and check if it works normally TH R14H SW TH REMO MAIN 2TH OP7 R18H R17H OP6 LO ST...

Page 58: ...t Room Temp MED LO AUTO JET Heater Defrost Filter Humidify Out door Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 3 4 FAN SPEED HI 2 Timer 1 2 3 5 4 Timer Procedure of RPM change Ex External Static pressure is 6mmAq for Model Name ABNH368GLAA To protect the unit compressor is designed to be off during E S P setting Push the On Off button The unit will start Push the Timer and Wind...

Page 59: ...8 7 660 17 2 607 16 5 583 210 17 600 16 1 569 15 6 551 14 7 519 14 494 60 34 2 1208 33 1 1169 31 7 1119 29 9 1056 27 7 978 26 918 165 27 954 26 3 929 26 1 922 25 8 911 24 8 876 23 812 195 21 742 20 8 735 20 6 727 20 4 720 20 4 720 20 706 1 42 1483 40 1413 38 1342 35 5 1254 33 5 1183 32 1130 220 39 1377 37 1307 35 1236 33 1165 31 1095 29 1024 240 34 1201 32 5 1148 31 1095 29 5 1042 27 954 26 5 936 ...

Page 60: ...lation A place where air circulation in the room will be good A place where drainage can be easily obtained A place where noise prevention is taken into consideration Do not install the unit near the door way Ensure sufficeient spaces as indicated by arrows from the wall ceiling or other obstacles More than 20cm More than eye level More than 20cm R R More than 20cm More than 20cm Ceiling installat...

Page 61: ...lants in the path of the warm air Take the air conditioner weight into account and select a place where noise and vibration are minimum Select a place so that the warm air and noise from the air conditioner do not disturb neighbors Rooftop Installations If the outdoor unit is installed on a roof structure be sure to level the unit Ensure the roof structure and anchoring method are adequate for the...

Page 62: ...t W 3 8 or M10 Nut W 3 8 or M10 Spring Washer M10 Plate Washer M10 Drill the piping hole on the wall slightly tilted to the outdoor side using a Ø 70 hole core drill Set screw of paper model 4 pieces Paper model for installation Ceiling board 150mm Adjust the same height Ceiling board Ceiling Flat washer for M10 accessory Keep the length of the bolt from the bracket to 40mm Open the ceiling board ...

Page 63: ...spension bolts for locking the suspension bolts on the ceiling Mount the suspension bolts to the set anchor firmly Secure the installation plates onto the suspension bolts adjust level roughly using nuts washers and spring washers CASE 2 POSITION OF CONSOLE BOLT M10 Nut M10 SP washer M10 washer X 4 X 4 Local supply X 4 M10 Nut M10 SP washer M10 washer X 4 X 4 Local supply X 4 1 Set anchor Old buil...

Page 64: ... L by removing each 2 screws on both sides Pull the upper right and left side of Inlet Grille to the front and it will stop at slightly tilted position Unhook the Inlet hanger from the Hanger screw on both left and right side Detach the Inlet Grille from the Indoor Unit 1 Installation on the ceiling Measure and mark the position for the Suspension bolts and the piping hole Drill the hole for ancho...

Page 65: ...the ceiling Mount the suspension bolts to the anchor nuts firmly Secure the Installation plates on Suspension bolts adjust level roughly using nuts washers and spring washers Engage 2 hooks on both left and right side of the unit to the lower slot of Installation Plates Adjust a level with a level gauge on the direction of left right back forth by adjusting suspension bolts Move the hooks on the u...

Page 66: ...stallation on the floor Installation of Mount Bracket Select and mark the position for Mount Brackets and the piping hole Drill the hole for the anchor nut on the wall Drill the piping hole using a ø70 hole core drill Secure the Mount Brackets on the wall with four M4 screws Install the indoor unit onto the Mount Brackets Engage the slot at the back of the unit with Mount Bracket 1076 more than 26...

Page 67: ... 0 75mm2 18K 24K 30K 1 25mm2 36k 48k 45k Capacity 1 Phase 3 Phase 18 24 30k BTU h 36K BTU h 48 54K BTU h 2 5mm2 5 5mm2 2 5mm2 3 5mm2 POWER INPUT 1 L 2 N 4 N 5 6 7 8 3 L 4 N 5 6 7 3 L Terminals on the indoor unit Terminals on the outdoor unit 1Phase Heat Pump Model 1Phase Cooling Model Only POWER INPUT Terminals on the indoor unit 1 L 2 N 4 N 5 7 6 8 3 L Terminals on the outdoor unit 4 N 5 6 7 3 L ...

Page 68: ...tening these screws install the air inlet grille including the air filter Decoration panel fixing screws hexagon M5 screws Temporally fitting at 2 places Tightening about 10mm Control box cover Piping side Inlet Grille Inlet Grille Inlet Grille Inlet Grille Inlet Grille Louver motor Decoration panel fixing screws Hexagon M5 screw Air conditioner unit Decoration panel Key holes Display Lead wire fo...

Page 69: ...rant piping gas piping thick piping and drain piping add further 10mm to 30mm thickness material Indoor unit Thermal insulator accessory Fastening band accessory Refrigerant piping HEAT INSULATION 1 Wrap the connecting portion of indoor unit with the Insulation material and secure it with two Plastic Bands for the right pipings If you want to connect an additional drain hose the end of the drain o...

Page 70: ...and pipe fittings The air conditioner uses a drain pump to drain water Use the following procedure to test the drain pump operation Connect the main drain pipe to the exterior and leave it provisionally until the test comes to an end Feed water to the flexible drain hose and check the piping for leakage Be sure to check the drain pump for normal operating and noise when electrical wiring is comple...

Page 71: ...00 Front of view Alway lay the drain with downward inclination 1 50 to 1 100 Prevent any upward flow or reverse flow in any part 5mm or thicker formed thermal insulator shall always be provided for the drain pipe CORRECT Install the P Trap or U Trap to prevent a water leakage caused by the blocking of intake air filter Applied U Trap Dimension 1 Decline Installation of indoor unit is very importan...

Page 72: ...themperature is controlled by the thermistor of the wired remote controller control the temperature according to the position of wired remote controller Position 3 The room temperature is controlled by lower temperature between the temperature of main body and of remote controller sensor 3 Move the slide switch to set position 4 Close the rear cover and check if it works normally TH R14H SW TH REM...

Page 73: ...ed in standard mode 3 Group Control Ceiling Cassette Ceiling Concealed duct model Be careful not to exchange the color of wires The maximum length of connecting wire should be below 200m 25Ω on connecting each units Use a wire more than 0 5mm2 CAUTION It operates maximum 16 Units by only one Wired Remote Controller and each Unit starts sequentially to prevent overcurrent Wiring design Operation un...

Page 74: ... at safe area where it is far away from the user Plasma air cleaner must be installed at appointed location All wiring and connections are for installation only 2 Attention Exchange the existing remote controller with an enclosed new remote controller while installing Be sure to turn off the power before removing the air cleaner unit for washing 3 Quantity Quantity Package contents 1 Plasma Air cl...

Page 75: ...ove the three brackets from the indoor unit 3 Open the rear panel 4 Remove all the tapes 5 Assemble the air cleaner 6 Connect the lead wire to control box through the bushings 7 The location of connecting terminal 8 Assemble the rear panel 9 Assemble the three brackets to the air cleaner 10 Insert the filter ...

Page 76: ...ire 3 Pull the sliding bracket 4 Remove the air cleaner kit 5 Wash the air cleaner kit 6 Dry the air cleaner kit in a shaded lot until all the water become dry up completely 7 Assemble the air cleaner 8 Insert the sliding bracket 9 Connect the lead wire 10 Assemble the side panel 5 How to maintain ...

Page 77: ...BPAEC 350 180 1235 ABPAEZ Model Dimension mm H D W No Location No P No Description Remark 1 159830 5983A10003C Air cleaner kit 2 266090 6609A10002A H V Assembly 6871A10008F ABPAHH 6871A10008G ABPAHC 6871A10008F ABPAGH 3 267110 6871A10008G Remote Controller ABPAGC 6871A10008D ABPAEH 6871A10008C ABPAEC 6871A10008E ABPAEZ W H D ...

Page 78: ...Electronic Control Device 78 Universal System Air Conditioner Electronic Control Device Ceiling Cassette Type 1 Main P C B ASM ...

Page 79: ...Electronic Control Device Service Manual 79 Ceiling Duct Type ...

Page 80: ...Electronic Control Device 80 Universal System Air Conditioner Ceiling Floor ...

Page 81: ...Schematic Diagram Service Manual 81 Ceiling Cassette Type Schematic Diagram ...

Page 82: ...R01S C01S 102 C03S 10K 103 R06S 10K R03S 20 R04S 2 2 103 C03S 3 3 1 1 DC 12V NC NC NC NC SCK P42 P05 P06 P02 P03 P04 P00 P01 P76 P77 P16 P17 P13 DVO P15 TC2 P14 PPG P12 INT2 TC1 P11 INT1 P10 INT0 P07 XIN REST P22 XOUT P21 XTIN TEST P20 INT5 STOP VSS XOUT P31 VSS P35 P34 P33 P32 SI1 P43 SI2 P46 SCK2 P46 SO1 P44 SO2 P47 P53 INT3 TC3 P50 PWM PDO P52 INT4 TC4 P51 VASS P54 VARF AIN0 P60 AIN3 P63 AIN1 P...

Page 83: ...Schematic Diagram Service Manual 83 Ceiling Duct Type BH BE Series ...

Page 84: ...Schematic Diagram 84 Universal System Air Conditioner Ceiling Floor RY 4WAY RY OUTFAN ...

Page 85: ...acement Parts List Service Manual 85 354211 249951 266090 268714 263230 1 266012 35211A 263230 2 352118 330870 158591 159830 249941 Exploded View and Replacement Parts List ATNC EL ATNH EL Ceiling Cassette Type 1 Indoor Unit ...

Page 86: ...86 Universal System Air Conditioner Exploded View and Replacement Parts List 346810 130411 359012 W0CZZ 267110 1 267110 2 130911 1 130911 2 ...

Page 87: ...Q3226F 6323AQ3226F 6323AQ3226F 6323AQ3226F R 266012 SWITCH ASSY FLOAT 6601A20001G 6601A20001G 6601A20001G 6601A20001G R 266090 H V ASSY 6609A20005C 6609A20005C R 267110 REMOTE CONTROLLER ASSEMBLY 6711A20039G 6711A20039J 6711A20039H 6711A20039K R 267110 REMOTE CONTROLLER ASSEMBLY 6711A20076K 6711A20076J R 330870 DRAIN PAN ASSEMBLY 3087A10002A 3087A10002A 3087A10002A 3087A10002A R 346810 MOTOR ASSY ...

Page 88: ...stem Air Conditioner Exploded View and Replacement Parts List 249951 266090 268714 330870 159830 263230 1 354211 1 158591 263230 2 352118 1 266012 552111 352118 2 354211 2 349490 ATNC FL ATNH FL Ceiling Cassette Type ...

Page 89: ...Service Manual 89 Exploded View and Replacement Parts List 346810 130411 359012 W0CZZ 267110 1 267110 2 130911 1 130911 2 ...

Page 90: ...6711A20039G 6711A20039J 6711A20039H 6711A20039K R 267110 REMOTE CONTROLLER ASSEMBLY 6711A20076K 6711A20076J R 268714 PWB PCB ASSEMBLY MAIN 6871A10105G 6871A10105G 6871A10105F 6871A10105F R 330870 DRAIN PAN ASSEMBLY 3087A10010B 3087A10010B 3087A10010B 3087A10010B R 346810 MOTOR ASSEMBLY INDOOR 4681A20051Z 4681A20051Z 4681A20051Z 4681A20051Z R 349490 ORIFICE ASSEMBLY 4949A10007A 4949A10007B 4949A100...

Page 91: ...AQ3226E 6323AQ3226E 6323AQ3226E R 267110 REMOTE CONTROLLER ASSEMBLY 6711A20039J 6711A20039K R 267110 REMOTE CONTROLLER ASSEMBLY 6711A20076B 6711A20076K 6711A20076A 6711A20076J R 330870 DRAIN PAN ASSEMBLY 3087A10010B 3087A10010B 3087A10010B 3087A10010B R 346810 MOTOR ASSEMBLY INDOOR 4681A20051W 4681A20051W 4681A20051W 4681A20051W R 349490 ORIFICE ASSEMBLY 4949A10007A 4949A10007B 4949A10007A 4949A10...

Page 92: ...tem Air Conditioner Exploded View and Replacement Parts List 266090 130411 354211 1 158591 330870 263230 352118 1 266012 552111 55211 2 159830 354211 2 249951 268714 263230 349490 ATNC DL ATNH DL Ceiling Cassette Type ...

Page 93: ...Service Manual 93 Exploded View and Replacement Parts List 130411 346810 359012 130911 3 130911 1 352150 2 W0CZZ 130911 4 130911 2 267110 1 267110 2 ...

Page 94: ...6323AQ3226F 6323AQ3226F 4995A20168A R 263230 2 THERMISTOR ASSEMBLY 6323AQ3226F 6323AQ3226F 4995A20168A R 266090 H V ASSEMBLY 6609A20005D 6609A20005D 6323AQ3226F R 267110 1 REMOTE CONTROLLER ASSEMBLY 6711A20039J 6711A20039K 6711A20039J R 267110 2 REMOTE CONTROLLER ASSEMBLY 6711A20076K 6711A20076J 6711A20076K R 330870 DRAIN PAN ASSEMBLY 3087A10006A 3087A10006A 3087A10006A R 346810 MOTOR ASSEMBLY IND...

Page 95: ...8A 4995A20168A 4995A20168A R 263230 2 THERMISTOR ASSEMBLY 4995A20168A 4995A20168A 4995A20168A R 266090 H V ASSEMBLY 6323AQ3226F 6323AQ3226F 6323AQ3226F R 267110 1 REMOTE CONTROLLER ASSEMBLY 6711A20039K 6711A20039J 6711A20039K R 267110 2 REMOTE CONTROLLER ASSEMBLY 6711A20076J 6711A20076K 6711A20076J R 330870 DRAIN PAN ASSEMBLY 3087A10006A 3087A10006A 3087A10006A R 346810 MOTOR ASSEMBLY INDOOR 4681A...

Page 96: ...r Exploded View and Replacement Parts List 346810 359012 2 354210 552111 152302 352118 330860 W0CZZ 268714 249951 336610 2 267110 1 263230 2 263230 1 267110 2 336610 1 359012 1 ATNC HL ABNC GL ATNH HL ABNH GL Ceiling Concealed Duct Type ...

Page 97: ... 5211A20465B 5211A20465B 5211A20465B 5211A20465B R 552111 TUBE ASSEMBLY CAPI 5211A20466J 5211A20466J 5211A20466H 5211A20466H R 33860 DRAIN PAN ASSEMBLY 3087A10008B 3087A10008B 3087A10008B 3087A10008B R 249951 CONTROL BOX ASSEMBLY 4995A10081A 4995A20164N 4995A10081B 4995A20164Q R 268714 PWB PCB ASSEMBLY 6871A10071P 6871A10071G 6871A10071Q 6871A10071H R 263230 1 THERMISTOR ASSY 6323AQ3226G 6323AQ322...

Page 98: ...5211A20450G 5211A20450G 5211A20450H 5211A20450H R 352118 TUBE ASSEMBLY MENIFOLD INDOOR 5211A20416A 5211A20416A 5211A20416A 5211A20416A R 330860 DRAIN PAN ASSEMBLY 3087A10008A 3087A10008A 3087A10008A 3087A10008A R 249951 CONTROL BOX ASSEMBLY INDOOR 4995A22003B 4995A22003A 4995A20164B 4995A20011W R 268714 PWB PCB ASSEMBLY MAIN 6871A20181J 6871A20181H 6871A20181B 6871A20181A R 263230 1 THERMISTOR ASS...

Page 99: ...xploded View and Replacement Parts List 152302 268714 35211C 2 35211C 1 267110 1 267110 2 346810 336610 1 336610 2 359012 2 359012 1 354210 W0CZZ 263230 1 263230 2 249951 330860 ABNC EL ABNH EL Ceiling Concealed Duct Type ...

Page 100: ...E INDOOR 5211A30077A 5211A30077A 5211A30077A 5211A30077A R 35211C 2 TUBE ASSY DISCHARGE INDOOR 5211A30094B 5211A30094B 5211A30077B 5211A30077B R 330860 DRAIN PAN ASSEMBLY 3086A30001H 3086A30001H 3086A30001H 3086A30001H R 249951 CONTROL BOX ASSEMBLY INDOOR 4995A20164K 4995A20164J 4995A20164K 4995A20164J R 268714 PWB PCB ASSEMBLY MAIN 6871A10040M 6871A10040M 6871A10040N 6871A10040N R 263230 1 THERMI...

Page 101: ...Replacement Parts List 130911 263230 35211A 342800 359010 152302 330870 354210 352115 261704 268714 W0CZZ 166000 1 346811 268712 237900 235450 146811 159911 1 166000 2 159911 2 352150 267110 137213 135314 AVNC BL AVNH BL Ceiling Floor Type ...

Page 102: ...98E R 263230 THERMISTOR ASSEMBLY 6323AQ2333Y 6323AQ2333Y 6323AQ2333Y R 267110 REMOTE CONTROLLER ASSEMBLY 6711A20010J 6711A20010K 6711A20010J R 268712 PWB PCB ASSY DISPLAY 6871AQ3263A 6871AQ3263A 6871AQ3263A R 268714 PWB PCB ASSY MAIN 6871A20042L 6871A20042H 6871A20042L R 330870 DRAIN PAN ASSEMBLY 3087AP7233A 3087AP7233A 3087AP7233A R 342800 BEARING 3H02821B 3H02821B 3H02821B R 346810 MOTOR ASSEMBL...

Page 103: ...THERMISTOR ASSEMBLY 6323AQ2333Y 6323AQ2333Y 6323AQ2333Y R 267110 REMOTE CONTROLLER ASSEMBLY 6711A20010K 6711A20010J 6711A20010K R 268712 PWB PCB ASSY DISPLAY 6871AQ3263A 6871AQ3263A 6871AQ3263A R 268714 PWB PCB ASSY MAIN 6871A20042H 6871A20042L 6871A20042H R 330870 DRAIN PAN ASSEMBLY 3087AP7233A 3087AP7233A 3087AP7233A R 342800 BEARING 3H02821B 3H02821B 3H02821B R 346810 MOTOR ASSEMBLY INDOOR 4681...

Page 104: ... Air Conditioner Exploded View and Replacement Parts List 669200 268713 268712 437212 552113 554160 W0CZZ 437211 559010 546810 552203 1 552203 2 554031 649950 435511 648600 552117 552112 435301 349480 Model No AUUC186A AB ...

Page 105: ...w and Replacement Parts List 554031 559010 435512 435301 349480 437211 546810 552113 552203 1 552203 2 552112 552116 548490 649950 435511 437212 561410 552114 W0CZZ 669200 648600 268713 554160 268712 Model No AUUH186A AB AUUC246A AB ...

Page 106: ...ent Parts List 435301 349480 268712 554031 546810 559010 552112 W0CZZ 552113 566001 268713 552202 566000 649950 554160 561410 552203 1 552203 2 437211 435512 263230 669200 552116 137213 1 435300 137213 2 Model No AUUH246A AB AUUC306A AB AUUH306A AB 2 OUTDOOR UNITS ...

Page 107: ...08A 5211A33008A R 552203 1 VALVE SERVICE 5220A20013A 5220A20013A 5220A20013A 5220A20013A R 552203 2 VALVE SERVICE 5220A20007A 5220A20007A 5220A20007A 5220A20007A R 554031 CONDENSER ASSEMBLY BENT 5403A20104C 5403A20104C 5403A20022R 5403A20022R R 554160 COMPRESSOR ASSEMBLY 5416A90023A 5416A90023A 5416A90023A 5416A90023A R 559010 FAN ASSEMBLY PROPELLER 5901A10032A 5901A10032A 5901A10032A 5901A10032A ...

Page 108: ...6B R 552114 TUBE ASSEMBLY DISCHARGE OUTDOOR 5211A21130A 5211A21130A R 552202 VALVE REVERSING 5220AR3228E 5220AR3228E R 552203 VALVE SERVICE 5220A20007A 5220A20007A 5220A20007A 5220A20007A R 552203 VALVE SERVICE 5220A20013A 5220A20013A 5220A20013A 5220A20013A R 554031 CONDENSER ASSEMBLY BENT 5403A20058D 5403A20058D 5403A10030A 5403A10030A R 554160 COMPRESSOR ASSEMBLY 2520UXDP2BA 2520UXDP2BA 5417A10...

Page 109: ...NG 5220AR3228L 5220AR3228L R 552203 1 VALVE SERVICE 5220A20013A 5220A20013A 5220A20013A 5220A20013A R 552203 2 VALVE SERVICE 5220A20007A 5220A20007A 5220A20007A 5220A20007A R 554031 CONDENSER ASSEMBLY BENT 5403A10030A 5403A10030A 5403A10030A 5403A10030A R 554160 COMPRESSOR ASSEMBLY 5416A90027A 5416A90027A 5416A90027A 5416A90027A R 559010 FAN ASSEMBLY PROPELLER 5901A10032A 5901A10032A 5901A10032A 5...

Page 110: ... and Replacement Parts List 546810 559010 554031 435512 135301 437211 137213 2 137213 1 135314 W0CZZ 1 W0CZZ 2 552112 552113 435511 430411 552203 1 548490 552203 2 552202 561410 554160 649950 268713 263230 269200 268712 Model No AUUC368A AB AUUH368A AB ...

Page 111: ...810 649950 268712 552203 1 548490 552203 2 435512 559010 561410 W6640 554031 1 554031 2 566001 W0CZZ 1 W0CZZ 2 552116 554160 566000 268713 437212 648600 669200 263230 437910 435511 137212 352115 352111 552201 Model No AUUC488A AB AUUH488A AB AUUC608A AB AUUH608A AB ...

Page 112: ...4008A 5211A24008A 5211A24008A R 552202 VALVE REVERSING 3A02080E 3A02080E 3A02080E 3A02080E R 552203 1 VALVE SERVICE 5220A20013B 5220A20013B 5220A20013B 5220A20013B R 552203 2 VALVE SERVICE 5220A20007A 5220A20007A 5220A20007A 5220A20007A R 554031 CONDENSER ASSEMBLY BENT 5403A20168B 5403A20168B 5403A20168B 5403A20168B R 554160 COMPRESSOR ASSEMBLY 2520UUCY2BA 2520UUCY2BA 2520UUCY2BA 2520UUCY2BA R 559...

Page 113: ... 4849A20009H 4849A20009H 4849A20009H 4849A20009H R W5210B TUBE CONNECTOR 5210AP7001R 5210AP7001R 5210AP7001R 5210AP7001R R 552202 VALVE REVERSING 3A02080B 3A02080B 3A02080B 3A02080B R 552203 1 VALVE SERVICE 5220A20001F 5220A20001F 5220A20001F 5220A20001F R 552203 2 VALVE SERVICE 2A00499L 2A00499L 2A00499L 2A00499L R 554160 COMPRESSOR ASSEMBLY 2520UBAY2BA 2520UBAY2BA 2520UBAY2BA 2520UBAY2BA R 55403...

Page 114: ...552203 1 VALVE SERVICE 5220A20006H 5220A20006H 5220A20006H 5220A20006H R 552203 2 VALVE SERVICE 2A00499L 2A00499L 2A00499L 2A00499L R 554031 1 CONDENSER ASSEMBLY BENT 5403A20193A 5403A20193A 5403A20193A 5403A20193A R 554031 2 CONDENSER ASSEMBLY BENT 5403A20193B 5403A20193B 5403A20193B 5403A20193B R 554160 COMPRESSOR ASSEMBLY 5416A90026A 5416A90026A 5416A90026A 5416A90026A R 559010 FAN ASSEMBLY PRO...

Page 115: ...Exploded View and Replacement Parts List Service Manual 115 152312 135314 137211 268712 146811 Model No PT HEA C PT CEA C ...

Page 116: ...152312 135314 137211 268712 146811 Exploded View and Replacement Parts List 116 Universal System Air Conditioner Model No PT HFA C PT CFA C ...

Page 117: ...152312 135314 135802 146811 137211 268712 Exploded View and Replacement Parts List Service Manual 117 Model No PT HDA C PT CDA C ...

Page 118: ...ILLE ASSEMBLY FRONT INDOOR 3531A10211A 3531A10211C 3531A10211A 3531A10211C R 135312 FILTER ASSY AIR CLEANER 5231A10012A 5231A10012A 5231A10012A 5231A10012A R 146811 MOTOR ASSEMBLY STEP 4681A20055A 4681A20055A 4681A20055A 4681A20055A R 268712 PWB PCB ASSEMBLY DISPLAY 6871A20096J 6871A20096J 6871A20096J 6871A20096J R PT CFA PT CFC PT HFA PT HFC LOCATION No DESCRIPTION Part No REMARKS 137211 PANEL AS...

Page 119: ...P No 3828A22009A Printed in Korea ...

Reviews: