Part 5. Trouble Shooting
- 92 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Check Point
1. Check the Input Voltage (L–N
➔
230V±10%)
2. Check Input Voltage Sensor output voltage (2.5Vdc±10%)
Is Inverter PCB Normal?
No
Replace inverter PCB assembly
Is input voltage normal ?
No
Check L~N Voltage is 230V±15%
Yes
< Input Power Source Check Point >
Recheck power and
installation condition
Yes
■
Error Diagnosis and Countermeasure Flow Chart
40
C/T
Sensor Error
• Initial current error
• Malfunction of current detection circuit.
(Open / Short)
• Check CT Sensor output voltage :
2.5Vdc ±5%
Display
code
Title
Cause of error
Check point & Normal condition
WARNING
Before checking PCB or each outdoor electric parts, wait for 3 minutes after the power is off. When measuring at standby state
of power supply, after checking the measurement mode of the meter, be careful of the short-circuits with other parts.
■
Error Diagnosis and Countermeasure Flow Chart
Summary of Contents for A2UW18GFA0