- 40 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 5. Trouble Shooting
1.3 Error Indicator (Outdoor)
Outdoor Error
Ex) Error 21 (DC Peack)
1 Time
1 Time
1 Time
2 Times
2 Times
2 Times
1 Sec.
2 Sec.
2 Sec.
1 Sec.
1 Sec.
LED01G
(RED)
LED02G
(GREEN)
◑
: A light on the display panel is blink.
Error
Code
Contents
LED01G/M
(Red)
LED02G/M
(Green)
case of Error
Outdoor
Status
21
DC Link Peak (IPM Fault)
2times
◑
1times
◑
Over Rated Current
Off
22
CT 2 (Max CT)
2times
◑
2times
◑
Input Over Current
Off
23
DC Link Low Volt.
2times
◑
3times
◑
DC Link Volt is below 140Vdc
Off
DC Link High Volt.
DC Link Volt is above 420Vdc
25
Low Voltage/Over Voltage
2times
◑
5times
◑
Abnormal AC Volt Input
Off
26
DC Compressor Position Error
2times
◑
6times
◑
Compressor Starting Fall Error
Off
27
PSC/PFC Fault Error
2times
◑
7times
◑
Over Inverter PCB input current
Off
29
COMP Over Current
2times
◑
9times
◑
Over Inverter Compressor Current
Off
32
D-Pipe High
3times
◑
2times
◑
D-Pipe Temp. High
Off
35
Low Pressure Error
3times
◑
5times
◑
Excessive decrease of Low Pressure
Off
39
Communication Error
3times
◑
9times
◑
Communication Error Between PFC
Micom and INV Micom
Off
40
CT Sensor (Open/Short)
4times
◑
○
CT Circuit Malfunction
Off
41
INV. D-Pipe Th Error
4times
◑
1times
◑
Open/Short
Off
43
High Pressure Sensor Error
4times
◑
3times
◑
Open/Short
Off
44
Outdoor Air Th Error
4times
◑
4times
◑
Open/Short
Off
45
Cond. Mid-Pipe Th Error
4times
◑
5times
◑
Open/Short
Off
46
Suction Pipe Th Error
4times
◑
6times
◑
Open/Short
Off
48
Cond. Out-Pipe Th Error
4times
◑
8times
◑
Open/Short
Off
51
Capacity Over
5times
◑
1times
◑
Over combination
Off
53
Signal Error (Indoor <-> Outdoor)
5times
◑
3times
◑
Communication Poorly
Off
54
3-Phase Wrong wiring
5times
◑
4times
◑
3-Phase Wrong Wring of Outdoor Unit
(Reverse Phase/Omission of Phase)
Off
60
EEPROM Check Sum Error
6times
◑
○
Check Sum Mismatching
Off
61
Cond. Pipe Th High
6times
◑
1times
◑
Cond. Temp. High
Off
62
Heaksink Th High
6times
◑
2times
◑
Heatsink Temp. High
Off
65
Heaksink Th Error
6times
◑
5times
◑
Open/Short
Off
67
Outdoor BLDC Fan Lock
6times
◑
7times
◑
Outdoor Fan is not operation
Off
73
PFC Fault Error(S/W)
7times
◑
3times
◑
Over Current of Outdoor Unit PFC
Off
Summary of Contents for A2UW18GFA0