August 2009 Plasma 50PS80
Y
Y
-
-
SUS
SUS
–
–
Vy and VSC Adjustments
Vy and VSC Adjustments
PROCEDURE: (See figures for locations)
4)
Adjust –Vy using VR902.
Measured across –Vy TPs R305.
Match your specific Panel’s Voltage
label ±1V.
1) Pre-Heat unit for at least 10 Minutes before making adjustments.
Vs and Va adjustments complete.
2) Place unit into White Wash from the Customer’s Menu for all adjustments.
3) Be sure to use all adjustment values as indicated on your panel’s
voltage label in the upper right of the panel. (Example shown above)
5)
Adjust VSC using VR901.
Measured across VSC TPs R306.
Match your specific Panel’s Voltage
label ±1V.
Location Bottom Center
-Vy VR902
VSC VR901
VSC TP R306
-Vy TP R305
Location Lower left
Location Lower Center