3-13
3.1.1.14
Large jitter
Large jitter
Large jitter
Large jitter
Cause
Cause
Cause
Cause
Relevant Unit
Relevant Unit
Relevant Unit
Relevant Unit
Check Method
Check Method
Check Method
Check Method
Maintenance Method
Maintenance Method
Maintenance Method
Maintenance Method
Remark
Remark
Remark
Remark
Power supply-main
control board
connection failure
None
Visual check
Connect the connector.
None
Power supply fails
Power supply
Tester check (+5V,
+24V, GND)
★
Replace the power
supply.
None
Motor-main control
PCBA connection
failure
None
Visual check
Connect the connector.
None
Motor failure
Motor
Visual check
Replace the motor.
None