82
Cleaning and maintenance
OptraImage 212/222, 312/322, Color 1200, T612
Cleaning the ADF
Clean the scan unit if documents do not feed smoothly or easily, or if several
documents feed at one time. The scan unit parts may be contaminated with ink,
toner particles or paper coatings.
1
Wet a clean, lint-free cloth or cotton swab with Isopropyl alcohol (95%).
2
Open the ADF unit and wipe the upper feeding roller by moving the swab
from side to side.
3
Rotate the roller forward with your finger and repeat the above cleaning
procedures until the entire roller is cleaned. Be careful not to snag or
damage the pick springs.
4
Wipe the pad in the direction from top to bottom. Be careful not to hook
the pick springs.
5
Close the ADF unit. Your scan unit is now ready for use.
Feeding roller
Pad assembly