Display and control panel AMS 384i
Leuze electronic GmbH + Co. KG
AMS 384
i
49
TNT
35/7-2
4V
8.4
Operation
An operating process is described here using parameter enable as an example.
Parameter enable
During normal operation parameters can be viewed only. If parameters are to be changed,
the
ON
menu item in the
Parameter -> Parameter handling -> Parameter enable
menu must be
activated. To do this, proceed as follows.
Viewing and editing parameters
As long as parameter enable is active, the entire AMS 384
i
display is inverted.
Note!
Changes to parameters via display entry have immediate effect.
If a password was stored, parameter enable is not possible until this password is entered;
see "Password for parameter enable" below.
In the main menu, press the enter button to
enter the
Parameter
menu.
Parameter
Parameter handling
Interbus
Position value
I/O
Other
Use the
buttons to select the
Param-
eter handling
menu item.
Press the enter button to enter the
Parameter
handling
menu.
Parameter handling
o Parameter enable
o
Password
Parameters to default
In the Parameter handling menu, use the
buttons to select the
Parameter enable
menu item.
Press the enter button to enter the
Parameter
enable
menu.
Parameter enable
o
OFF
o ON
In the Parameter enable menu, use the
buttons to select the
ON
menu item.
Press the enter button to activate parame
-
ter enable.
Parameter enable
o
OFF
ON
The PWR LED lights up orange; the display
is inverted. You can now set the individual
parameters on the display.
Press the ESC button twice to return to the
Parameter menu.
ESC
ESC