Display and control panel AMS 384i
Leuze electronic GmbH + Co. KG
AMS 384
i
41
TNT
35/7-2
4V
8.2.2
LED status indicators
PWR LED
Off
Device OFF
- No supply voltage
Flashing green
Power LED flashes green
- No measurement value output
- Voltage connected
- Self test running
- Initialization running
- Parameter download running
- Boot process running
Green continuous light
Power LED green
- AMS 384
i
OK
- Measurement value output
- Self test successfully finished
- Device monitoring active
Red flashing
Power LED flashes red
- Device OK but warning message (ATT, TMP, LSR)
set in display
- Light beam interruption
- Plausibility error (PLB)
Red continuous light
Power LED red
- No measurement value output; for details, see
display
Orange continuous light
Power LED orange
- Parameter enable active
- No data on the host interface
BUS LED
Flashing green
BUS LED flashes green
- Initialization of the AMS 384
i
- Interbus interface (SUPI) is being initialized.