Diagnostics and troubleshooting
56
AMS 384
i
Leuze electronic GmbH + Co. KG
10
Diagnostics and troubleshooting
10.1
Service and diagnosis in the display of the AMS 384
i
In the main menu of the AMS 384
i
, expanded "Diagnostics" can be called up under the
Service
heading.
From the
Service
main menu, press the enter button to access the underlying menu level.
Use the up/down buttons
to select the corresponding menu item in the selected level;
use the enter button to activate the selection.
Return from any sub-level to the next-higher menu item by pressing the ESC button .
10.1.1 Status messages
The status messages are written in a ring memory with 25 positions. The ring memory is orga
-
nized according to the FIFO principle. No separate activation is necessary for storing the
status messages. Power OFF clears the ring memory.
Basic representation of the status messages
n: Type / No. / 1
Meaning:
n:
memory position in the ring memory
Type:
type of message:
I = info, W = warning, E = error, F = severe system error.
No:
internal error detection
1:
frequency of the event (always "1" because no summation occurs)
The status messages within the ring memory are selected with the up/down buttons
.
Use the enter button to call up detailed information about the respective status message:
Service
Status messages
Diagnosis
Expanded diagnosis
ESC
Status messages
1: - / - / -
2: - / - / -
3: - / - / -