System commands for serial interfaces
Commands can be sent to the sensor via UART index 2
System Command
.
Table 8.12:
System commands
Command
Value
Function / description
Dec.
Hex
Device Reset
128
d
80
h
Software
reset
Factory reset
130
d
82
h
Reset to factory settings
Activation
176
d
B0
h
Sensor illumination ON
Deactivation
177
d
B1
h
Sensor illumination OFF
UART Boot
180
d
B4
h
Start UART boot loader
Teach: on trace mode 4
192
d
C0
h
Trace width, trace amplitude, minimum contrast
Teach: angle compensation measure-
ment
193
d
C1
h
Angle
compensation
teach
Teach: on trace mode 1
194
d
C2
h
Trace width only
Teach: on trace mode 2
195
d
C3
h
Minimum contrast only
Teach: on trace mode 3
196
d
C4
h
Trace amplitude only
Dark trace, light background
212
d
D4
h
Light trace, dark background
213
d
D5
h
Retro-reflective trace
214
d
D6
h
Mode: "Trace width" filter ON
229
d
E5
h
Mode: "Trace width" filter OFF
230
d
E6
h
Mode: "Minimum contrast" filter ON
231
d
E7
h
Mode: "Minimum contrast" filter OFF
232
d
E8
h
Mode: "Trace amplitude" filter ON
233
d
E9
h
Mode: "Trace amplitude" filter OFF
234
d
EA
h
Delete angle compensation factors
240
d
F0
h
Delete error
242
d
F2
h
Delete error bits / error status