Configuring the sensor – Overview of functions
Leuze electronic
OGS 600
44
TNT
35/7-2
4
V
7.6.5
Index overview for the "Minimum contrast" filter
Bit counting method: bit0 … bit15
Table 7.6:
Index accesses for the "Minimum contrast" filter
Name
Index
UART
Index
[sub-
index]
CANopen
Index
length
[byte]
Access
Data / (default
value)
Info
Activate filter
2
d
2000
h
[0
h
]
2
W
231
d
System
command
Deactivate filter
2
d
2000
h
[0
h
]
2
W
232
d
System
command
Teaching the minimum
contrast
2
d
2000
h
[0
h
]
2
W
195
d
System
command
TraceContrastMin
103
d
2010
h
[4
h
]
2
RW
(5500
d
)
Result from teach or manual entry, unit:
[LSB]
TraceContrastWarning
104
d
2010
h
[5
h
]
2
RW
(20
d
)
Factor for calculation of warning thresh-
old, unit [%]
TraceContrastTol
105
d
2010
h
[6
h
]
2
RW
(30
d
)
Tolerance is used in teach event, unit:
[%]
Status
200
d
2020
h
[1
h
]
2
R
Bit no. 6
1 = Minimum contrast error
See also process data status byte, bit
no. 4 (Chapter 8.1.4.1)
Status
200
d
2020
h
[1
h
]
2
R
Bit no. 3
1 = Minimum contrast warning
See also process data status byte, bit
no. 1 (Chapter 8.1.4.1)
UserMode
75
d
2002
h
[0
h
]
2
R
Bit no. 3
If bit = 1, then "Minimum contrast" filter
is active.