Configuring the sensor – Overview of functions
Leuze electronic
OGS 600
40
TNT
35/7-2
4
V
7.5.1
Teaching the trace width
The
TraceWidthTol
parameter (UART Index 102
d
and CAN Index 2010
h
[3
h
]) is used during
the teach in order to define the upper and lower limit for the trace width on the basis of the
currently measured trace width.
Calculation of the values in the sensor:
Trace width =
│
Position of left edge - Position of right edge
│
TraceWidthMax
= Trace width +
TraceWidthTol
TraceWidthMin
= Trace width -
TraceWidthTol
7.5.2
Manual configuration of the trace width
If the trace width is to be configured manually, the values can be written directly to the
parameters
TraceWidthMax
(UART index 100
d
and CAN index 2010
h
[1
h
]) and
Trace-
WidthMin
(UART index 101
d
and CAN index 2010
h
[2
h
]).
Remember to apply the factor 10 during conversion: 10
d
corresponds to 1mm.
7.5.3
Process data information for the "Trace width" filter
If the number of detected traces which, owing to the "Trace width" filter, are not output in the
process data is greater or equal to one, then bit 3 is set in process data byte 2
Status PD
.
CAUTION
If a trace width teach is performed, manually configured trace width values are overwritten.