3x cable bushing, M16 x 1.5
2
SERVICE: Mini-B USB socket (behind protective cap)
Figure 3.3: Connection hood MK 301, connections
Cable fabrication and shielding connection
Remove approx. 78 mm of the connection cable sheathing.
15 mm of sheath of the shielded line must be freely accessible.
Lead the individual wires into the terminals according to the diagram.
1
Diameter of contact area, cable: 6 … 9.5 mm
2
Diameter of contact area, shield: 5 … 9.5 mm
Figure 3.4: Cable fabrication for connection hoods with spring-cage terminals
3.2.3 Connection hood KB 301 with cable
With connection hood KB 301, it is possible to directly connect the BPS. A Mini-B type USB socket is used
for service purposes and for configuration and diagnostic of the BPS.
The length of the connection cable is 3 m.
Contained in the MK 301 are the address switches for setting the bus address and the integrated
parameter memory for easily exchanging the BPS. Both the settings as well as the bus address
are stored in the MK 301 and automatically transmitted to the device on every device start-up.
NOTICE
Do not use wire-end sleeves!
When fabricating cables, we recommend against using wire-end sleeves.
The shield is automatically contacted when the cable is lead into the metal screw fitting and fas
-
tened when the cord grip is closed.
1
2
1
1
≈ 55 mm
≈ 8 mm
≈ 15 mm
1
2