Technical data
Leuze electronic
BCL 600i/BCL 601i
77
Electrical connection
The required core cross-section of the connection cable for the voltage supply must be at least 0.75 mm
²
.
Power consumption
The energy requirement depends on the model:
• the line scanner with heating typically consumes 40 W and a maximum of 50 W power.
• the line scanner with oscillating mirror and heating typically consumes 60 W and a maximum of
75 W.
These values are based on operation with unconnected switching outputs.
15.2.1 Line scanner with heater
Technical data same as for line scanner without heating, however with the following differences:
Table 15.11:
Specifications of the line scanners with heating
CAUTION
The voltage supply must not be looped through from one device to the next.
Type
BCL 600i
Stand alone or multiNet plus
master
BCL 601i
multiNet plus slave
Design
Line scanner with heater
Electrical data
Operating volt
-
age
24 V DC ±20 %
Power
consumption
Max. 50 W
Structure of the
heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30 min at +24 V DC and an ambient temperature of -35 °C
Min. conductor
cross section
Conductor cross section of at least 0.75 mm
²
for the supply-voltage line. Wiring
through of the voltage supply to multiple heating devices is not permissible. Standard,
M 12 ready-made cable is not usable (insufficient cable cross-section)
Environmental data
Operating tem
-
perature range
-35 °C … +40 °C
Storage temper
-
ature range
-20 °C … +70 °C