A switching output can be activated:
• At the start/end of the reading gate
• Depending on the read result:
• Reference code comparison positive/negative
• Read result valid/invalid
• Depending on the state of the device:
• Ready/not ready
• Data transmission active/not active
• Active/standby
• Error/no error
• etc.
Connect the required switching outputs (see chapter 7).
Configure the connected switching outputs according to your requirements. To do this, first set the I/O
mode to Output and then configure the switching behavior.
In webConfig: Configuration -> Device -> Switching inputs/outputs
Or alternatively in the display: Parameter -> Digital SWIO -> Switching input/output 1-4
10.6 Transmitting configuration data
Instead of going through the tedious task of configuring every parameter of the device individually, you can
also conveniently transfer configuration data.
In general, there are two possibilities for transferring configuration data between two bar code readers:
• Storage in a file and transfer using the webConfig tool
• Using the external parameter memory
10.6.1 Via the webConfig tool
With the webConfig tool, you can store entire configurations of the device on data carriers and transfer
them from these to the device.
This storage of configuration data is especially useful if you want to store basic configurations which will
require only minor changes.
In the webConfig tool, you store the configuration data via the buttons in the upper part of the middle
window of all submenus of the Configuration main menu.
10.6.2 With the external parameter memory
The use of the external parameter memory permits the easy replacement of a defective device on site.
This requires an external parameter memory to be installed permanently to the USB connection of the
device.
The device stores a copy of the current configuration in the external parameter memory. This copy is
immediately updated when the configuration is changed via the display or by a superior host system (PC/
PLC) via online commands.