Online commands
Leuze electronic
BCL 600i/BCL 601i
68
Writing parameter set
Acknowledgment
positive
PT<BCC><PS type><Status><Addr.><P.value addr.><P.val1>…
[;<Addr.><P.value addr.>]
<BCC>
0
No check digits
3
BCC mode 3
<PS type>
0
Parameter values stored in the flash memory
3
Operating values stored in RAM
<Status>
0
No further parameters
1
Additional parameters follow
<Addr.>
Relative address of the data within the data set
aaaa Four-digit,
unit [dimensionless]
<P.value> Parameter value of the -bb- parameter stored at this address.
The parameter set data is converted from HEX format to a
2-byte-ASCII format for transfer.
Acknowledgment
negative
PS=<aa>
<aa>
Status acknowledgment,
unit [dimensionless]
0
No difference
1
Syntax error
2
Impermissible command length
6
Impermissible combination, parameter set 1 and parameter set 2
8
Invalid parameter set
Command
PD
Command
PT
Description
The parameters of the device are grouped together in a parameter set and
permanently stored in memory. There is one parameter set in permanent
memory and one operating parameter set in volatile memory; in addition,
there is a default parameter set (factory parameter set) for initialization. This
command can be used to edit the first two parameter sets (in permanent and
volatile memory). A check sum can be used for reliable parameter transfer.