Display and control panel AMS 301i
43
AMS 301
i
Leuze electronic
I/O submenu
Table 8.4:
I/O submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
I/O 1
Port config-
uration
Input/Output
Defines whether I/O 1 functions as an output or input.
Output
Switching
input
Function
No function/preset teach/laser ON/OFF
No function
Activation
Low active/High active
Low active
Switching
output
Function
Pos. limit value 1 / Pos. limit value 2 / Velocity / Intensity (ATT) /
Temp. (TMP) / Laser (LSR) / Plausibility (PLB) / Hardware (ERR)
The individual functions are "ORed" on the selected switching
output.
Plausibility (PLB),
hardware (ERR)
Activation
Low active/High active
Low active
I/O 2
Port config-
uration
Input/Output
Defines whether I/O 2 functions as an output or input.
Output
Switching
input
Function
No function/preset teach/laser ON/OFF
No function
Activation
Low active/High active
Low active
Switching
output
Function
Pos. limit value 1 / Pos. limit value 2 / Velocity / Intensity (ATT) /
Temp. (TMP) / Laser (LSR) / Plausibility (PLB) / Hardware (ERR)
The individual functions are "ORed" on the selected switching
output.
Intensity (ATT),
Temp. (TMP),
Laser (LSR)
Activation
Low active/High active
Low active
Limit values
Upper pos.
limit 1
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0
Lower pos.
limit 1
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0
Upper pos.
limit 2
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0
Lower pos.
limit 2
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0