Specifications
Leuze electronic
AMS 301
i
12
TNT
35/7-2
4
V
Inputs/outputs
Quantity
Input
Output
2, programmable
protected against polarity reversal
max. 60 mA, short-circuit proof
Mechanical data
Housing
cast zinc and aluminum
Optics
glass
Weight
approx. 2.45 kg
Protection class
IP 65 acc. to EN 60529
4)
Environmental conditions
Operating temperature
without device heating
with device heating
-5 °C … +50 °C
-30 °C … +50 °C
5)
Storage temperature
-30 °C … +70 °C
Air humidity
max. 90 % rel. humidity, non-condensing
Mechanical/electrical loading capacity
Vibrations
acc. to EN 60068-2-6
Noise
acc. to EN 60060-2-64
Shock
acc. to EN 60068-2-27
EMC
acc. to EN 61000-6-2 and EN 61000-6-4
6)
1)
Statistical error: 1 sigma; minimum switch-on time: 2 min.
2)
For UL applications: only for use in "Class 2" circuits acc. to NEC.
3)
Switching off the laser diode during system downtime can considerably extend the life expectancy of
the device. The laser life expectancy is calculated using a failure rate of 1%.
4)
With screwed-on M 12 plugs or mounted caps.
5)
With devices with heating, the switch on/off area of the internal heating can be extended to prevent
condensation from forming. A 100% prevention of the formation of condensation cannot be
guaranteed due to the limited heating capacity of the AMS 301
i
.
6)
This is a Class A product. In a domestic environment this product may cause radio interference, in
which case the operator may be required to take adequate measures.