Display and control panel AMS 301i
Leuze electronic
AMS 301
i
42
TNT
35/7-2
4
V
Position value submenu
Position
resolution
0.01 mm / 0,1 mm / 1 mm / 10 mm / free mm
The measurement value can be displayed in these resolutions.
The value of the free resolution is determined in the "Position value"
submenu in the "Value of free resolution" parameter.
0.1 mm
Velocity
resolution
1 / 10 / 100
1
Table 8.3:
Position value submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Measurement
unit
Metric/Inch
Specifies the units of the measured distances.
Metric
Count direction
Positive/Negative
Positive: The measurement value begins at 0 and increases with increas-
ing distance.
Negative: The measurement value begins at 0 and decreases with
increasing distance. Negative distance values may need to be compen-
sated with an offset or preset.
Positive
Offset
Output value=measurement value+offset.
The resolution of the offset value is independent of the selected "Reso-
lution position" and is entered in mm or inch/100. The offset value is
effective immediately following entry. If the preset value is activated, this
has priority over the offset. Preset and offset are not offset against each
other.
0 mm
Preset
The preset value is accepted by means of teach pulse. The teach pulse
can be applied to a hardware input of the M 12 PWR connector. The hard-
ware input must be appropriately configured. See also configuration of
the I/Os.
0 mm
Free resolution
value
The measurement value can be resolved in increments of 1/1000 within
the 5 … 50000 value range. If, e.g., a resolution of 0.875 mm per digit
is required, the parameter is set to 875.
In the activated interface, the measurement value display must also be
set to "free resolution" ("Resolution position" parameter).
1000
Error delay
ON / OFF
Specifies whether, in the event of an error, the position value immediately
outputs the value of the "Position value in the case of error" parameter
or the last valid position value for the configured error delay time.
ON/100 ms
Position value in
the case of error
Last valid value / zero
Specifies which position value is output after the error delay time elapses.
Zero
Table 8.2:
RS 485 submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard