Display and control panel AMS 301i
Leuze electronic
AMS 301
i
38
TNT
35/7-2
4
V
8.2.2
LED status displays
PWR LED
Off
Device OFF
- No supply voltage
Flashing green
Power LED flashes green
- No measurement value output
- Voltage connected
- Self test running
- Initialization running
- Boot process running
Green continuous light
Power LED green
- AMS 301
i
ok
- Measurement value output
- Self test successfully finished
- Device monitoring active
Red flashing
Power LED flashes red
- Device ok but warning message
(ATT, TMP, LSR) set in display
- Light beam interruption
- Plausibility error (PLB)
Red continuous light
Power LED red
- No measurement value output; for details, see Display
BUS LED
Flashing green
BUS LED flashes green
- Initialization of the host interface
Green continuous light
BUS LED green
- Host interface active