Unidrive M200-201 Quick Start Guide
43
Issue Number: 7
Used to define the unique address for the drive for the serial interface. The drive is always a slave,
address 0 is used to globally address all slaves, and so this address should not be set in this
parameter.
Changing the parameters does not immediately change the serial communications settings. See
Reset Serial Communications
(Pr
45
) for more details.
Set to On (1) to update communications set-up.
Defines the upper current threshold for the brake. See Brake Controller Brake Release in
Parameter
Reference Guide
.
Defines the lower current limit for the brake. See Brake Controller Brake Release in
Parameter
Reference Guide
.
44
Serial Address
RW
Num
US
OL
Ú
1 to 247
Ö
1
RFC-A
45
Reset Serial Communications
RW
Bit
ND
NC
US
OL
Ú
Off (0) or On (1)
Ö
Off (0)
RFC-A
The display will briefly display On and return to Off on reset.
46
Brake Controller Upper Current Threshold
RW
Num
US
OL
Ú
0 to 200 %
Ö
50 %
RFC-A
47
Brake Controller Lower Current Threshold
RW
Num
US
OL
Ú
0 to 200 %
Ö
10 %
RFC-A
NOTE