![Lenze L-force 930 fluxxtorque Mounting Instructions Download Page 71](http://html.mh-extra.com/html/lenze/l-force-930-fluxxtorque/l-force-930-fluxxtorque_mounting-instructions_1882550071.webp)
Electrical installation
Electrical connections 931WxNx0
71
MA 13.1002 DE−EN DE/EN 1.1
X1 RS232
Contact pattern
Pin no.
Signal
1
TxD
2
GND (ground)
3
RxD
X5 digital input, digital output (option)
Contact pattern
Pin No. Signal
Function
Specification
1
DC + 24 V
Control voltage DC + 24 V ± 10 %
2
DIN0
Digital input 0
Rated voltage
DC + 24 V
HIGH signal
DC 18 ... 30 V
LOW signal
DC 0 ... 4 V
Cycle time
Maximally 0.5
ms
3
GND
Reference potential for control voltage
4
DOUT0
Digital output 0
Output voltage
DC + 24 V
LOW signal
DC 0 ... 4 V
HIGH signal
DC 18 ... 30 V
Output current
Maximally 0.5 A
Cycle time
Maximally 0.5
ms
Short−circuit−proof
X5 local CAN (option)
Contact pattern
Pin No. Signal
Specification
1
DC + 5 V
Voltage supply
2
CAN_H
CAN HIGH
3
CAN_GND CAN Ground
4
CAN_L
CAN LOW