Technical data
Rated data
931WxNx0 servo inverter
57
MA 13.1002 DE−EN DE/EN 1.1
Type
931WxNx0
230 V
AC
320 V
DC
Open and closed loop control
Control method
Torque, speed, following error and position control
Cycle time
Current controller
t [
m
s]
£
100
Speed controller
Minimally 500
Following error
Position controller
Chopper frequency (PWM)
f [kHz]
10
Max. output frequency
f [Hz]
500
Positioning range
Revolutions
± 2
19
Storable function data records
100
Encoder evaluation
Resolver (12 bit internal resolution)
Monitoring
Over/undervoltage, temperature of the motor and the
output stage
1) The information refers to the torque indicated on the motor shaft. In these values,
the friction torque of the motor is also considered!