Electrical installation
Electrical connections 931MxNx1
69
MA 13.1002 DE−EN DE/EN 1.1
X5 local CAN (option)
Contact pattern
Pin No. Signal
Specification
1
DC + 5 V
Voltage supply
2
CAN_H
CAN HIGH
3
CAN_GND CAN Ground
4
CAN_L
CAN LOW
X4.1 / X4.2 PROFIBUS (option)
Input contact pattern
Pin No. Signal
Specification
1
n. c.
Not assigned
2
RxD/TxD−N
Receive / Transmit data −N (A line)
3
DGND
Data Ground (reference potential to VP)
4
RxD/TxD−P
Receive / Transmit data −plus (B line)
5
Shield
Shield
Output contact pattern
Pin No. Signal
Specification
1
VP
Power supply plus (5V)
2
RxD/TxD−N
Receive / Transmit data −N (A line)
3
DGND
Data Ground (reference potential to VP)
4
RxD/TxD−P
Receive / Transmit data −plus (B line)
5
Shield
Shield
1
CAN_SHLD
CAN_Shield
2
Reserved
3
CAN_GND
CAN_Ground
4
CAN_H
CAN_HIGH (high is
dominant)
5
CAN_L
CAN_LOW (low is dominant)