background image

Dimensions of KK6 power terminal box

m1

n3

k4

m2

P1 P2

g3

g1

n2

P6

x5

Motor

m540-P

90/L4

100/M4

112/M4

132/M4

160/M4

160/L4

 

100/L4

 

132/L4

 

 

Gearbox

 

 

 

 

 

 

 

 

  g500-H5000

x

5

mm

205

227

219

273

257

317

  g500-H8000

x

5

mm

-

226

217

267

250

310

  g500-H14000

x

5

mm

-

-

205

254

237

297

Terminal box

 

 

 

 

 

 

 

 

   

g

1

mm

154

171

182

207

241

241

   

m

1

mm

123

135

135

162

180

180

   

n

2

mm

120

135

135

162

180

180

   

P1

mm

M20x1.5

M32x1.5

M32x1.5

M32x1.5

M40x1.5

M40x1.5

   

P2

mm

M25x1.5

M32x1.5

M32x1.5

M32x1.5

M40x1.5

M40x1.5

   

k

4

mm

32

32

32

0

0

0

   

m

2

mm

95

95

95

107

107

107

   

n

3

mm

105

105

105

105

105

105

   

P

6

mm

1x M16x1.5

1x M16x1.5

1x M16x1.5

1x M16x1.5

1x M16x1.5

1x M16x1.5--

Motor

m540-P

-P180/M4

-P180/L4

-P200/M4

-P225/M4

-P225/L4

-P250/M4

Gearbox

 

 

 

 

 

 

 

 

  g500-H5000

x

5

mm

316

346

406

415

475

 

  g500-H8000

x

5

mm

310

340

399

405

463

481

  g500-H14000

x

5

mm

296

326

386

388

448

463

Terminal box

 

 

 

 

 

 

 

 

   

g

1

mm

292

292

315

408

408

457

   

m

1

mm

197

197

197

233

233

299

   

n

2

mm

265

265

266

319

319

374

   

P1

mm

M40x1.5

M40x1.5

M50x1.5

M63x1.5

M50x1.5

M63x1.5

   

P2

mm

M40x1.5

M40x1.5

M50x1.5

M63x1.5

M50x1.5

M63x1.5

   

k

4

mm

0

0

0

0

0

0

   

m

2

mm

107

107

107

107

107

107

   

n

3

mm

105

105

105

105

105

105

   

P

6

mm

1x M16x1.5

1x M16x1.5

1x M16x1.5

1x M16x1.5

1x M16x1.5

1x M16x1.5

Product extensions

Motor connection

Assignment of the terminal boxes

80

Summary of Contents for IE3 g500-H

Page 1: ...Geared motors IE3 g500 H m540 P helical geared motor Project planning EN...

Page 2: ......

Page 3: ...n on project planning 14 Safety instructions 14 Basic safety instructions 15 Application as directed 16 Foreseeable misuse 16 Residual hazards 17 General information 19 Drive dimensioning 22 Final con...

Page 4: ...duct extensions 77 Motor connection 77 Connection options 77 Assignment of the terminal boxes 78 Assignment of the connectors HAN 82 Connection via terminal box 84 Connection via HAN connector 86 Brak...

Page 5: ...ent includes safety instructions which must be observed All persons working on and with the drives must have the documentation at hand during work and observe the information and notes relevant for it...

Page 6: ...er documentation with additional information Example EDKxxx see documentation EDKxxx Layout of the safety instructions DANGER Indicates an extremely hazardous situation Failure to comply with this ins...

Page 7: ...ndardized flanges for easy machine integration High efficiency Three phase AC motors for mains and inverter operation In a power range from 1 5 to 55 kW Lenze offers inverter compatible three phase AC...

Page 8: ...lange according to IEC 72 DIN 42948 Torsional vibration damping power transmission of the coupling Motor shaft connection low backlash or backlash free depending on version More information can be fou...

Page 9: ...ary Oil drain plug depending on the mounting position Temperature monitoring Feedback Cooling Brake Output shaft Output flange Housing type Ventilation depending on the mounting position Oil filler pl...

Page 10: ...M6 ABCDEF Combined Color Primed Painted in RAL colors Surface and corrosion protection OKS S Different types of OKS Output shaft Solid shaft with featherkey mm 70 x 140 90 x 170 110 x 210 Solid shaft...

Page 11: ...serve the available gearbox designs 4The modular system 10 Solid shaft with foot Without centering VBR Solid shaft without foot With centering VCR Flange with through holes VCK Product information The...

Page 12: ...of the defined positions refer to the areas on the geared motor in mounting position M1 A Position of the built on accessories with T L R B F E Top Left Right Bottom Front and End If the geared motor...

Page 13: ...x Blower terminal box HAN connector with without ICN connector with without ICN connector R L B T R L B T R L B T Positions of the connections HAN connector R L E Position of the manual release lever...

Page 14: ...personal injury and damage to property Observe all specifications of the corresponding documentation supplied This is the precondition for safe and trouble free operation and for obtaining the product...

Page 15: ...ccording to the appropriate regulations e g cable cross sections fusing PE conductor connection Additional information can be obtained from this documentation This documentation contains notes about i...

Page 16: ...C Directive 2014 30 EU The product is not a household appliance Instead it is a component that is intended exclusively for further use in the context of commercial or professional use as defined by EN...

Page 17: ...ipment or wait until the device has cooled down Prevent contact with flammable substances Risk of injury from rotating parts Before working on the drive system ensure that the motor is at a standstill...

Page 18: ...ed on the nameplate Lateral forces on the gearbox shaft are possible Align the shafts of gearboxes and driven machine exactly to each other Toothed parts may be damaged by a lack of lubricant Only use...

Page 19: ...MA MS MK MN IA IN 0 2 0 4 0 6 0 8 nN nS nK 0 0 M MN n nN 1 0 2 3 4 5 I IN Operation on the frequency inverter Standard setting The frequency inverter is set for easy operation on a three phase AC moto...

Page 20: ...C D m540 P A Operation with integral fan and brake B Operation with integral fan and brakes with a wide range voltage of DC 180 205 V or AC 400 460 V Operation with integral fan and holding current re...

Page 21: ...e drive speeds given in the following are exceeded as a function of the mounting position Temporarily up to 5 min 30 higher speeds are permissible the ambient temperature is predominantly above 30 C G...

Page 22: ...ne correction factor Operating modes and operating time Ambient temperature and installation height Determine gearbox type and efficiency Determine product on the basis of the active forces Calculate...

Page 23: ...h Determine correction factor Operating modes S1 S2 S3 S6 and operating time Operating mode S1 Operating mode S2 Operating mode S3 Operating mode S6 ED kL ED kL ED kL ED kL min 100 1 0 10 1 4 1 5 15...

Page 24: ...k kL Correction factor operating mode kTU Correction factor ambient temperature kH Correction factor site altitude G Gearbox efficiency Intensity and load class for mains operation Calculation Intens...

Page 25: ...on factor Sh Switching rate Ratio of motor stalling torque rated torque 2 5 Ratio of motor stalling torque rated torque 2 5 Stalling rated motor torque 4Rated data 100 Check and select product Data 4S...

Page 26: ...m Min Output speed Self ventilated n21 nL min rpm Adjustment range 2 5 50 Hz Adjustment range 4 35 87 Hz Forced ventilated n22 nL min rpm Adjustment range 10 50 Hz Adjustment range 17 4 87 Hz Self ven...

Page 27: ...be chosen for the top coat Surface and corrosion protection Applications Product g500 H5000 H14000 g500 S8000 S19000 g500 B8000 B20000 OKS G primed Dependent on subsequent top coat applied Optionally...

Page 28: ...3 years 4 years At oil temperature 80 C Manufacturer Fuchs Kl ber Shell Fuchs Kl ber Fuchs Kl ber Shell Manufacturer series Renolin Unisyn Kl bersyn th Omala Cassida Fluid Kl beroil Renolin Unisyn Kl...

Page 29: ...30 mm has to be observed to the machine wall on the corresponding gearbox side g500 H5000 H14000 Mounting position M1 A Mounting position M2 D Mounting position M3 B Filling and ventilation Check Drai...

Page 30: ...gh filling level is required in the gearbox As a result of the reduced volume of air in the gearbox this may lead to oil escaping from the ventilation at higher input speeds The oil compensation reser...

Page 31: ...Dimensions of oil compensation reservoir Gearbox A1 L2 mm mm g500 H5000 376 166 g500 H8000 399 336 g500 H14000 427 336 Information on project planning Final configuration Ventilation 31...

Page 32: ...parts Only use safely fixed transport aids e g eye bolts or support plates Do not damage any components during transport Avoid electrostatic discharges on electronic components and contacts Avoid impa...

Page 33: ...e system or machine is responsible for adherence to the limits required in connection with EMC legislation Operation on an external inverter A max pulse voltage amplitude of Upk 1560 V at the motor te...

Page 34: ...per hr TV 30 40 C Site altitude 1000 m above sea level The selection tables indicate the mechanically permissible power levels and torques The ratings apply to the operating mode S1 acc to EN 60034 NO...

Page 35: ...Protection of persons and device protection Protection class EN EN 60529 EN 60034 5 IP55 Information applies to the mounted and ready for use state IP65 Temperature class Utilization EN 60034 1 B 130...

Page 36: ...the last digits of the product name e g g500 B110 110 Nm g500 H5000 2 stage gearboxes Output speed Max output torque Ratio Number of teeth Max backlash Standard n2 M2 max i zg zt rpm Nm 303 3270 4 846...

Page 37: ...819 6 4 3 5000 344 169 523481 1521 6 3 9 5000 372 850 523481 1404 6 g500 H8000 2 stage gearboxes Output speed Max output torque Ratio Number of teeth Max backlash Standard n2 M2 max i zg zt rpm Nm 36...

Page 38: ...7 40 7 7 5 8000 195 242 75168 385 7 6 6 8000 219 799 307719 1400 7 5 9 8000 247 950 4959 20 7 5 5 8000 264 509 157383 595 7 5 2 8000 281 041 157383 560 7 4 4 8000 328 381 321813 980 7 g500 H14000 2 st...

Page 39: ...2 3 14000 65 723 4272 65 6 18 4 14000 80 123 31328 391 6 16 2 14000 90 945 54112 595 6 14 7 14000 99 061 11392 115 6 13 1 14000 111 686 5696 51 6 11 8 14000 125 283 244928 1955 6 10 5 14000 140 406 25...

Page 40: ...n positive power transmission Suitable for reversing duty Tension ring hub without keyway Non positive power transmission Suitable for reversing duty Versions with plug in hollow shaft Adapter Plug in...

Page 41: ...10 FT350 T70 735 768 835 37 0 45 0 225 60 140 FT400 T76 788 816 881 55 0 250 65 140 FT500 T81 820 853 915 75 0 90 0 280 75 140 FT500 T82 729 792 Versions with plug in hollow shaft Motor Adapter Gearbo...

Page 42: ...4 625 9 000 A28 697 731 798 324 326 TC 2 125 5 250 11 000 A32 781 808 873 364 365 TC 2 375 5 875 11 000 A36 828 862 923 Versions with plug in hollow shaft Motor Adapter Gearbox g500 Size Shaft Size H...

Page 43: ...ith jaw coupling Motor Adapter Gearbox g500 Shaft Size H5000 H8000 H14000 M d l M L L L mm mm mm mm mm mm mm 130 24 50 FT130 E06 491 165 32 58 FT165 E08 527 565 633 215 38 80 FT215 E10 594 627 694 300...

Page 44: ...d perm fw x Frad max Permissible axial force If there is no radial force the maximum axial force is 50 of the value in the table Frad max Fax zul 0 5 x Frad max Application of forces l x Fax Frad Addi...

Page 45: ...her forces can be transmitted Please get in touch with your Lenze representative Max radial force gearbox with foot VBR Getriebe Output speed n2 rpm 250 160 100 63 40 25 Max radial force Frad max N g5...

Page 46: ...11000 13000 13500 13500 13500 13500 g500 H8000 23000 25000 25000 25000 25000 25000 g500 H14000 35100 35100 35100 35100 35100 Reinforced bearings Getriebe Output speed n2 rpm 250 160 100 63 40 25 Max...

Page 47: ...ion Geared motor Mains operation 5 Hz 20 Hz 50 Hz 1 10 87 Hz 1 17 4 n22 M22 n21 M2 n2 M2 c n2 M2 c J i z m rpm Nm rpm Nm rpm Nm rpm Nm kgcm2 kg 1 1 682 5 5 1240 11 0 1240 4 0 19 5 1240 4 0 65 000 130...

Page 48: ...188 1 3 831 6 7 1507 13 3 1507 5 3 23 4 1507 5 3 177 000 110 259 g500 H8000 m540 P100 M4 3 270 1 3 862 6 4 1563 12 8 1563 3 2 22 5 1563 3 2 159 000 114 361 g500 H5000 m540 P100 M4 3 188 1 2 928 6 0 1...

Page 49: ...0 H8000 m540 P100 L4 3 270 1 1 1350 5 6 2452 11 2 2452 2 0 19 6 2452 2 0 156 000 130 842 g500 H5000 m540 P100 L4 3 188 1 0 1427 5 3 2591 10 6 2591 3 1 18 6 2591 3 1 166 000 138 255 g500 H8000 m540 P10...

Page 50: ...9 3082 2 6 20 9 3082 2 6 201 000 123 043 g500 H8000 m540 P112 M4 3 270 1 2 1724 5 8 3138 11 7 3138 4 5 20 5 3138 4 5 244 000 125 283 g500 H14000 m540 P112 M4 3 415 1 1 1800 5 6 3277 11 2 3277 1 5 19 6...

Page 51: ...2735 5 1 32 2 2735 5 1 472 000 80 123 g500 H14000 m540 P132 M4 3 443 1 7 1621 8 5 2945 17 0 2945 2 7 29 9 2945 2 7 392 000 86 290 g500 H8000 m540 P132 M4 3 298 1 6 1689 8 2 3069 16 3 3069 1 6 28 7 306...

Page 52: ...P132 M4 3 298 0 5 5099 2 7 9263 5 4 9263 1 5 9 5 9263 1 5 363 000 271 398 g500 H14000 m540 P132 M4 3 443 0 5 5280 2 6 9592 5 2 9592 0 8 9 2 9592 0 8 349 000 281 041 g500 H8000 m540 P132 M4 3 298 0 5 5...

Page 53: ...796 2 9 43 0 2796 2 7 545 000 59 819 g500 H8000 m540 P132 L4 3 298 2 3 1611 11 7 2929 23 4 2929 1 7 41 1 2929 1 6 504 000 62 664 g500 H5000 m540 P132 L4 3 216 2 3 1630 11 8 2964 23 4 2964 1 7 41 2 296...

Page 54: ...L4 3 298 0 7 5670 3 3 10312 6 6 10312 1 4 11 7 10312 1 4 493 000 220 580 g500 H14000 m540 P132 L4 3 443 0 6 6264 3 0 11392 6 0 11392 1 2 10 6 11392 1 2 488 000 243 679 g500 H14000 m540 P132 L4 3 443 0...

Page 55: ...8 1 7 61 8 2888 1 7 844 000 41 819 g500 H5000 m540 P160 M4 2 228 3 4 1603 17 5 2913 35 0 2913 2 6 61 3 2913 2 6 860 000 42 182 g500 H8000 m540 P160 M4 2 307 3 3 1629 17 0 2962 33 9 2962 2 7 59 4 2962...

Page 56: ...9411 0 9 856 000 138 255 g500 H8000 m540 P160 M4 3 314 1 0 5258 5 3 9557 10 5 9557 1 5 18 4 9557 1 5 894 000 140 406 g500 H14000 m540 P160 M4 3 459 0 9 5855 4 7 10643 9 4 10643 1 3 16 5 10643 1 3 884...

Page 57: ...2 7 1040 000 30 392 g500 H8000 m540 P160 L4 2 324 4 4 1703 22 5 3097 44 9 3097 4 5 78 6 3097 4 3 1084 000 32 881 g500 H14000 m540 P160 L4 2 463 4 3 1736 22 1 3157 44 0 3157 1 6 77 1 3157 1 5 1010 000...

Page 58: ...1 7 1102 000 90 945 g500 H14000 m540 P160 L4 3 476 1 5 4991 7 6 9074 15 1 9074 0 9 26 4 9074 0 9 1033 000 97 753 g500 H8000 m540 P160 L4 3 331 1 5 5058 7 5 9196 14 9 9196 1 5 26 1 9196 1 5 1091 000 99...

Page 59: ...1 g500 H14000 m540 P180 M4 2 538 5 4 1736 27 2 3156 54 3 3156 2 5 95 3 3156 2 4 1359 000 27 067 g500 H8000 m540 P180 M4 2 399 5 2 1778 26 1 3232 52 3 3232 2 5 91 7 3232 2 1 1433 000 28 128 g500 H8000...

Page 60: ...1 687 g500 H8000 m540 P180 L4 2 404 6 2 1785 31 4 3245 62 8 3245 1 5 110 3245 1 3 1433 000 23 410 g500 H5000 m540 P180 L4 2 325 6 2 1788 31 3 3251 62 7 3251 4 3 110 3251 3 6 1554 000 23 451 g500 H1400...

Page 61: ...M2 c n2 M2 c J i z m rpm Nm rpm Nm rpm Nm rpm Nm kgcm kg 1 3 8392 6 6 15258 13 2 15258 0 9 23 1 15258 0 9 1485 000 111 686 g500 H14000 m540 P180 L4 3 556 1 2 9413 5 9 17115 11 7 17115 0 8 20 6 17115 0...

Page 62: ...4 39 5 3516 79 0 3516 1 4 139 3516 1 2 2247 000 18 599 g500 H5000 m540 P200 M4 2 395 7 7 1968 38 8 3579 77 7 3579 3 9 136 3579 3 3 2403 000 18 930 g500 H14000 m540 P200 M4 2 613 7 5 2010 38 0 3655 76...

Page 63: ...3348 1 2 4269 000 14 435 g500 H5000 m540 P225 M4 2 440 9 2 2000 47 0 3651 93 9 3651 2 2 164 3651 1 8 4327 000 15 743 g500 H8000 m540 P225 M4 2 519 8 8 2086 45 1 3808 90 0 3808 1 3 158 3808 1 1 4257 0...

Page 64: ...5 2 0 187 3915 1 7 4850 000 13 870 g500 H8000 m540 P225 L4 2 554 10 2 2196 52 3 3994 105 3994 3 5 183 3994 2 9 5008 000 14 149 g500 H14000 m540 P225 L4 2 693 10 0 2240 51 3 4075 102 4075 1 2 179 4075...

Page 65: ...M4 2 793 12 7 2152 65 0 3907 130 3907 2 1 228 3531 1 9 8703 000 11 377 g500 H8000 m540 P250 M4 2 654 12 7 2153 65 0 3908 130 3908 1 2 228 3533 1 1 8595 000 11 381 g500 H5000 m540 P250 M4 2 575 11 5 2...

Page 66: ...E84AVXXX1834 22 m540 P180 L4 E84AVXXX2234 30 m540 P200 M4 E84AVXXX3034 37 m540 P225 M4 E84AVXXX3734 45 m540 P225 L4 E84AVXXX4534 Rated frequency 87 Hz Rated power Motor Inverter kW 2 6 m540 P90 L4 E8...

Page 67: ...P 90 L4 100 M4 100 L4 Table content Explanation Total length L Total length of the drive without brake feedback Motor length LB Length of the motor without brake feedback Motor diameter AC Motor diame...

Page 68: ...25L4 250M4 Total length L mm 723 767 767 843 875 935 948 978 1041 1067 1127 1127 Motor length LB mm 349 393 393 469 501 561 574 604 667 693 753 753 Motor diameter AC mm 174 198 222 264 318 318 353 353...

Page 69: ...225L4 250M4 Total length L mm 723 767 767 843 875 935 948 978 1041 1067 1127 1127 Motor length LB mm 349 393 393 469 501 561 574 604 667 693 753 753 Motor diameter AC mm 174 198 222 264 318 318 353 3...

Page 70: ...225L4 250M4 Total length L mm 723 767 767 843 875 935 948 978 1041 1067 1127 1127 Motor length LB mm 349 393 393 469 501 561 574 604 667 693 753 753 Motor diameter AC mm 174 198 222 264 318 318 353 35...

Page 71: ...225L4 250M4 Total length L mm 805 805 876 908 968 981 1011 1074 1095 1155 1206 Motor length LB mm 391 391 462 494 554 567 597 660 681 741 792 Motor diameter AC mm 222 198 264 318 318 353 353 393 439 4...

Page 72: ...225L4 250M4 Total length L mm 805 805 876 908 968 981 1011 1074 1095 1155 1206 Motor length LB mm 391 391 462 494 554 567 597 660 681 741 792 Motor diameter AC mm 222 198 264 318 318 353 353 393 439...

Page 73: ...4 225L4 250M4 Total length L mm 873 943 975 1035 1048 1078 1141 1160 1220 1268 Motor length LB mm 379 449 481 541 554 584 647 666 726 774 Motor diameter AC mm 222 264 318 318 353 353 393 439 439 487 M...

Page 74: ...M4 225L4 250M4 Total length L mm 873 943 975 1035 1048 1078 1141 1160 1220 1268 Motor length LB mm 379 449 481 541 554 584 647 666 726 774 Motor diameter AC mm 222 264 318 318 353 353 393 439 439 487...

Page 75: ...pring applied brake and feedback L mm 242 364 350 Forced ventilated motors Motor m540 P 90 L4 100 M4 112 M4 132 M4 160 M4 180 M4 100 L4 132 L4 160 L4 180 L4 Without feedback brake L mm 85 0 81 5 81 0...

Page 76: ...0 H5000 g500 H8000 g500 H14000 Foot m kg 16 0 26 0 44 0 Flange m kg 22 3 36 4 36 4 Motors Motor m540 P 90 L4 100 M4 112 M4 132 M4 160 M4 180 M4 200 M4 225 M4 250 M4 100 L4 132 L4 160 L4 180 L4 225 L4...

Page 77: ...y frequency Mains voltage Mains voltage range Circuit Hz V V 50 400 380 420 Y 230 220 240 60 460 440 480 Y The motors are rated to the specified line voltage range According to DIN EN 60034 the motors...

Page 78: ...brake Terminal box KK6 KK6 KK6 KK6 KK6 KK6 KK6 KK6 KK6 Product extension feedback Terminal box KK7 KK7 KK7 KK7 KK7 KK7 KK7 KK6 KK6 Product extension brake feedback Terminal box KK7 KK7 KK7 KK7 KK7 KK...

Page 79: ...254 237 297 Terminal box g1 mm 126 166 177 202 237 237 m1 mm 79 0 112 112 130 145 145 n2 mm 93 0 135 135 135 175 175 P1 mm M20x1 5 M32x1 5 M32x1 5 M32x1 5 M40x1 5 M40x1 5 P2 mm M25x1 5 M32x1 5 M32x1 5...

Page 80: ...mm 105 105 105 105 105 105 P6 mm 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 Motor m540 P P180 M4 P180 L4 P200 M4 P225 M4 P225 L4 P250 M4 Gearbox g500 H5000 x5 mm 316 346 406 415...

Page 81: ...107 n3 mm 105 105 105 105 105 105 P6 mm 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 Motor m540 P P180 M4 P180 L4 P200 M4 P225 M4 P225 L4 P250 M4 Gearbox g500 H5000 x5 mm 316 346...

Page 82: ...ctor is only available for motors with the Y connection method Motor m540 P 90 L4 100 M4 112 M4 132 M4 160 M4 180 M4 200 M4 225 M4 250 M4 100 L4 132 L4 160 L4 180 L4 225 L4 HAN 10E connector Connectio...

Page 83: ...7 219 g500 H8000 x5 mm 226 226 217 g500 H14000 x5 mm 205 Terminal box g4 mm 154 171 171 182 x2 mm 46 46 46 46 m5 mm 123 135 135 135 n5 mm 120 135 135 135 k4 mm 32 32 32 32 m2 mm 95 95 95 95 n3 mm 105...

Page 84: ...n of the terminal box Shown here T L R or B If required the terminal box can be rotated step by step by 90 after loosening the screws in the terminal box Power connection Bridge arrangement Y connecti...

Page 85: ...Zero track RS485 0 0 Zero track inverse RS485 Connection of temperature monitoring Terminal box temperature monitoring Contact Name Meaning TB1 Temperature monitoring TCO TB2 1TP1 PTC150 thermistor 2...

Page 86: ...or is only suitable for motors with the connection method Y HAN 10E connector assignment 1 2 3 4 5 6 7 8 9 10 Bridge arrangement in the HAN 10E mating connector Contact Name Meaning 6 7 8 Y Connection...

Page 87: ...h before the rectifier AC voltage switching as well as after the rectifier DC voltage switching The choice of control system influences the engagement time of the armature plate inter alia AC switchin...

Page 88: ...m a high speed and in the event of emergency stops the braking torque is significantly reduced Permissible friction energy 18 16 14 10 08 06 12 1 10 100 1000 10000 10 100 1000 10000 100000 1000000 S h...

Page 89: ...x 106 Friction lining Low wear Options Manual release UL CSA approved Braking torques An application brake with several braking torques is available for every motor frame size for an optimum adjustmen...

Page 90: ...namic braking torque Min dynamic braking torque tolerance 25 25 25 25 25 25 25 25 25 25 Max dynamic braking torque tolerance 35 35 35 35 35 35 35 35 35 35 100 rpm Nm 4 0 4 0 8 0 8 0 8 0 8 0 16 16 20 2...

Page 91: ...40 38 38 60 60 Min static braking torque tolerance 25 25 25 25 25 25 25 25 25 25 Max static braking torque tolerance 35 35 35 35 35 35 35 35 35 35 Dynamic braking torque Min dynamic braking torque tol...

Page 92: ...80 80 150 150 Min static braking torque tolerance 25 25 25 25 25 25 25 25 25 25 Max static braking torque tolerance 35 35 35 35 35 35 35 35 35 35 Dynamic braking torque Min dynamic braking torque tole...

Page 93: ...Moment of inertia kgcm 73 73 73 73 73 73 200 200 Braking torque is static Nm 145 145 260 260 315 315 Min static braking torque tolerance 25 25 25 25 25 25 Max static braking torque tolerance 35 35 35...

Page 94: ...ngagement time t1 Direct connection without rectifier ms 180 165 150 Half wave or bridge rectifier ms 180 165 150 Friction energy QBW Direct connection without rectifier MJ 4680 2322 3489 Half wave or...

Page 95: ...00 H8000 k5 mm 509 539 607 617 674 675 732 733 754 754 g500 H14000 k5 mm 495 525 594 604 657 658 717 718 736 736 Brake k mm 74 74 74 103 103 69 103 69 69 65 h5 mm 319 319 319 445 445 330 445 330 330 3...

Page 96: ...230 230 400 230 230 400 230 230 400 Rated power Prated kW 0 065 0 091 0 091 0 075 0 091 0 091 0 094 0 1 0 1 Rated current Irated A 0 29 0 38 0 22 0 3 0 37 0 22 0 37 0 35 0 2 Motor series m540 P Size 1...

Page 97: ...e Widerstands nderung Operating temperature C 155 Min operating temperature tolerance C 5 Max operating temperature tolerance C 5 Temperature C 20 Rated resistance 155 C 1330 140 C 550 20 C 100 Motor...

Page 98: ...shaft with featherkey V Solid shaft without featherkey G Housing type Foot mounting centering A Foot mounting B With centering C Flange mounting Without flange R Flange with through holes K Reinforced...

Page 99: ...e 090 100 112 132 160 180 200 225 250 Overall length Medium M Long L Number of poles 4 pole 04 Protection class IP55 5 IP65 6 Cooling Self ventilation E Forced ventilation F Brake Without 0 Spring app...

Page 100: ...18 7 400 V Irated Y A 3 15 4 40 5 90 7 90 10 8 Starting current Ia A 22 7 37 0 49 0 56 1 92 9 Rated torque Mrated Nm 9 91 14 3 19 6 26 2 35 7 Starting torque Ma Nm 26 8 45 8 49 0 62 9 104 Stalling to...

Page 101: ...100 Prated 0 904 0 914 0 921 0 926 0 930 Moment of inertia J kgcm 460 830 990 1300 1400 Weight m kg 57 0 73 0 90 0 165 170 Motor m540 P 200 M4 225 M4 225 L4 250 M4 Rated power Prated kW 30 37 45 55 R...

Page 102: ...895 0 917 Moment of inertia J kgcm 49 0 140 140 170 340 Weight m kg 15 0 29 0 29 0 29 0 57 0 Motor m540 P 132 L4 160 M4 160 L4 180 M4 180 L4 Rated power Prated kW 7 5 11 15 18 5 22 Rated speed nrated...

Page 103: ...0 71 0 84 0 Starting current Ia A 389 435 511 638 Rated torque Mrated Nm 161 198 241 294 Starting torque Ma Nm 483 555 699 823 Stalling torque Mb Nm 564 595 723 941 Power factor cos 0 83 0 85 0 84 0...

Page 104: ...0 920 Moment of inertia J kgcm 49 0 140 140 170 340 Weight m kg 15 0 29 0 29 0 29 0 57 0 Motor m540 P 132 L4 160 M4 160 L4 180 M4 180 L4 Rated power Prated kW 13 1 19 2 26 3 32 2 38 5 Rated speed nrat...

Page 105: ...ed voltage Delta Urated V 400 400 400 400 Rated current 400 V Irated A 98 4 119 143 154 Rated torque Mrated Nm 195 239 291 320 Power factor cos 0 83 0 85 0 86 0 86 Efficiency at 50 Prated 0 928 0 916...

Page 106: ...emperature C 20 40 Maximum operating temperature C 155 Potentially explosive atmospheres No operation in explosive atmospheres Rated efficiency at full load N 89 5 88 6 89 6 91 7 90 4 91 7 91 4 92 4 E...

Page 107: ...ally explosive atmospheres No operation in explosive atmospheres Rated efficiency at full load N 93 9 94 5 94 2 95 94 6 95 4 Efficiency at 75 rated load 94 5 94 7 94 9 95 3 95 1 95 6 Efficiency at 50...

Page 108: ...ded exposure of substances to humans animals and the environment is excluded Lenze products are industrial electrical and electronic products and are disposed of professionally Both the mechanical and...

Page 109: ...energy efficiency requirements in the USA and Canada C ULUS UL certificate for products tested according to US and Canada standards C URUS UL certificate for components tested according to US and Cana...

Page 110: ...tL tB Sequence of identical duty cycles comprising operation with a constant load and subsequent standstill Start up and braking processes do not have an impact on the winding temperature The steady s...

Page 111: ...ction against vertically dripping water dripping water 2 Protection against medium sized foreign particles d 12 mm keeping away fingers or the like 2 Protection against diagonally falling water drippi...

Page 112: ...04 2021 1 0 www Lenze com...

Reviews: