27
Further documents
Operating instructions I510-Cabinet
8.4 LED status
LED “RDY” (blue)
LED “ERR” (red)
Status/meaning
Off
Off
No supply voltage.
Mains voltage is switched on, inverter is initialized.
(1 s on, 1 s off)
Off
Inverter is disabled, ready for operation.
(0.25 s on, 0.25 s off)
Safe torque off (STO) active, warning active.
(0.5 s on, 0.5 s off)
off
Inverter disabled.
(0.25 s on, 0.25 s off)
Inverter disabled, warning active.
Inverter disabled, error active.
(Lights up briefly once every
1.5 s)
Inverter disabled, no DC-bus voltage.
off
Inverter enabled.
off
The motor rotates according to the specified setpoint
or quick stop active.
(0.25 s on, 0.25 s off)
Inverter enabled, warning active.The motor rotates
according to the specified setpoint or active “Quick
stop” function.
(1 s on, 1 s off)
Inverter enabled, quick stop as response to fault
active.
9 Further documents
For certain tasks, information is available in further documents.
Document
Contents/topics
Project planning document
Fundamental information on project planning and ordering the product
Commissioning document
Fundamental information for the installation and commissioning of the pro-
duct
Mounting instructions
Fundamental information on mounting the product
The documents can be found in the Lenze Doc Finder.
10 Disposal
If pollutants are disposed off improperly, they may cause a lasting damage to human health
and the environment. Thus, electrical and electronic equipment must be collected separately
from unsorted municipal waste so that it may be recycled or disposed of properly.
If available, put the components to the company internal disposal from where it is passed on
to specialised waste management companies.
It is also possible to return the components to the manufacturer. For this purpose, please
contact the customer service of the manufacturer.
More detailed information on disposal can be obtained from the corresponding specialist
firms and the competent authorities.
The packaging of the component must be disposed of separately. Paper, cardboard and
plastics must be recycled.
11 Glossary
Abbreviation
Meaning
AIE
Error acknowledgement (“Acknowledge In Error”)
OFF state
Signal status of the safety sensor when it triggers or responds
QSP
Quick stop