9300 Servo PLC
System blocks
2.12
MCTRL_MotorControl
2-62
L
ServoPLC EN 2.0
2.12.17.8
OH4 - Heatsink temperature monitoring (adjustable)
This monitoring function protects the controller.
No. Monitoring function
Display System variable
TRIP
Message Warning
Off
054 Heatsink temperature (adjustable)
OH4
MCTRL_bKuehlGreaterC0122_b
•
ü
•
Default setting
ü
Setting possible
This monitoring function sends a warning before the controller is switched off because of a TRIP (OH)
using the function “Heatsink temperature (fixed)”.
•
Thus, the process can be influenced to avoid a switch-off of the controller at an inconvenient
time.
•
Additionally, fans which would cause an unacceptable noise in continuous operation, can also
be switched on and off.
MCTRL_bKuehlGreaterC0122_b
is derived from a comparator with hysteresis.
•
The threshold can be set under C0122:
Code
LCD
Possible settings
IMPORTANT
o
Lenze
Selection
C0122 OH4 limit
85
Temperature threshold prewarning
heatsink temperature “Tht > C0122”
(error OH4)
45
{1 °C}
85
•
The hysteresis is 5 K (fixed), i.e. the monitoring is reset at 5 K below the threshold set.
•
The response is set under C0852:
Code
LCD
Possible settings
IMPORTANT
o
Lenze
Selection
C0582 MONIT OH4
2
Configuration monitoring
2
Warning
3
Off
efesotomasyon.com - Lenze