Commissioning
Initial switch−on
EDKMF2178IB DE/EN/FR 6.0
70
l
H2_FirstOn−LEDs_KommModul_BT
Initial switch−on
)
Note!
Follow the commissioning steps in the given order!
1. Switch on the standard device and, if necessary, the external voltage supply of the
communication module.
– The green LED
0
on the front of the communication module is lit.
– The status LED of the standard device (Drive LED)
2
must be lit or blinking. The
meaning of the signalling can be found in the standard device documentation.
2. You can now communicate with the drive, i. e.
– all parameters (SDO) can be read;
– all writable parameters (SDO) can be overwritten.
3. After a state change ("Operational") process data can be exchanged with the drive.
2172CAN000D
Fig. 7
LEDs of the communication module