_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.2
Possible causes and remedies
This chapter lists all EtherCAT error messages in the numerical order of the error numbers. Possible
causes and remedies as well as responses to the error messages are described in detail.
EtherCAT: Connection to 9400 lost [0x00c83100]
EtherCAT: Internal supply voltage too low [0x00c85114]
EtherCAT: Memory: No access [0x00c85531]
EtherCAT: Memory: Error while reading [0x00c85532]
EtherCAT: Memory: Error while writing [0x00c85533]
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
The MXI communication to the Servo Drive 9400 is
interrupted.
• Servo Drive 9400 is switched off.
• The communication module is not connected
correctly at the MXI slot of the Servo Drive 9400.
• Switch on Servo Drive 9400.
• Plug in the communication module correctly at the
MXI slot of the Servo Drive 9400.
• Send communication module and Servo Drive 9400
with error description to Lenze.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Voltage loss of the standard device
Check voltage supply.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Access to memory was not possible.
Send communication module together with a
description of the fault to Lenze.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Parameter could not be read.
Send communication module together with a
description of the fault to Lenze.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Parameter could not be written.
Send communication module together with a
description of the fault to Lenze.